NITROGEN-FILLED LIPOSOMES AS A VASCULAR US CONTRAST AGENT - PRELIMINARY EVALUATION

被引:73
作者
UNGER, EC [1 ]
LUND, PJ [1 ]
SHEN, DK [1 ]
FRITZ, TA [1 ]
YELLOWHAIR, D [1 ]
NEW, TE [1 ]
机构
[1] IMAR PHARMACEUT CORP,TUCSON,AZ
关键词
BLOOD; US; CONTRAST MEDIA; EXPERIMENTAL STUDIES; HEART; LIPOSOMES; ULTRASOUND; (US);
D O I
10.1148/radiology.185.2.1410353
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Liposomes with a mean diameter of 1-2 mum were made to entrap nitrogen gas and tested as an ultrasound (US) contrast agent. The gas-filled liposomes, or Aerosomes (ImaR(x) Pharmaceutical, Tucson) were tested in vitro for size, stability, reflectivity, and acoustic characterization, and were tested in vivo for acute toxicity in mice and for cardiac imaging in rabbits after intravenous injection. Aerosomes have much greater reflectivity and higher attenuation than do standard liposomes and retain their acoustic properties after storage in aqueous media for several months. The interpolated median lethal dose of Aerosomes is approximately 2.5 mmol of lipid per kilogram, and the imaging dose is under 5 mumol of lipid per kilogram, yielding a potential therapeutic index of over 500 to 1. Postcontrast US images showed sustained enhancement of all four cardiac chambers as well as enhancement in the aorta, vena, cava, and hepatic veins. Aerosomes hold promise as a contrast agent for cardiac and blood-pool imaging. Further work is in progress to characterize and develop this novel US contrast agent.
引用
收藏
页码:453 / 456
页数:4
相关论文
共 18 条
[1]   PHYSICAL AND ACOUSTICAL PROPERTIES OF PERFLUOROOCYTLBROMIDE, AN ULTRASOUND CONTRAST AGENT [J].
ANDRE, M ;
NELSON, T ;
MATTREY, R .
INVESTIGATIVE RADIOLOGY, 1990, 25 (09) :983-987
[2]  
CAROLL BA, 1980, INVEST RADIOL, V15, P260
[3]   SAFETY AND EFFICACY OF A NEW TRANSPULMONARY ULTRASOUND CONTRAST AGENT - INITIAL MULTICENTER CLINICAL-RESULTS [J].
FEINSTEIN, SB ;
CHEIRIF, J ;
TENCATE, FJ ;
SILVERMAN, PR ;
HEIDENREICH, PA ;
DICK, C ;
DESIR, RM ;
ARMSTRONG, WF ;
QUINONES, MA ;
SHAH, PM .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1990, 16 (02) :316-324
[4]   DETAILED TOXICITY STUDIES OF LIPOSOMAL GADOLINIUM-DTPA [J].
FRITZ, T ;
UNGER, E ;
WILSONSANDERS, S ;
AHKONG, QF ;
TILCOCK, C .
INVESTIGATIVE RADIOLOGY, 1991, 26 (11) :960-968
[5]   SH-U-508, A TRANSPULMONARY ECHOCONTRAST AGENT - INITIAL EXPERIENCE [J].
FRITZSCH, T ;
HILMANN, J ;
KAMPFE, M ;
MULLER, N ;
SCHOBEL, C ;
SIEGERT, J .
INVESTIGATIVE RADIOLOGY, 1990, 25 :S160-S161
[6]   PRECLINICAL AND CLINICAL-RESULTS WITH AN ULTRASONIC CONTRAST AGENT [J].
FRITZSCH, T ;
SCHARTL, M ;
SIEGERT, J .
INVESTIGATIVE RADIOLOGY, 1988, 23 :S302-S305
[7]   IV-INJECTION OF AIR-FILLED HUMAN-ALBUMIN MICROSPHERES TO ENHANCE ARTERIAL DOPPLER SIGNAL - A PRELIMINARY-STUDY IN RABBITS [J].
HILPERT, PL ;
MATTREY, RF ;
MITTEN, RM ;
PETERSON, T .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1989, 153 (03) :613-616
[8]  
HYKES D, 1985, ULTRASOUND PHYSICS I
[9]   PERFLUOROCHEMICALS AS US CONTRAST AGENTS FOR TUMOR IMAGING AND HEPATOSPLENOGRAPHY - PRELIMINARY CLINICAL-RESULTS [J].
MATTREY, RF ;
STRICH, G ;
SHELTON, RE ;
GOSINK, BB ;
LEOPOLD, GR ;
LEE, T ;
FORSYTHE, J .
RADIOLOGY, 1987, 163 (02) :339-343
[10]   CONTRAST AGENTS IN DIAGNOSTIC ULTRASOUND [J].
OPHIR, J ;
PARKER, KJ .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1989, 15 (04) :319-333