EVALUATION OF SEVERAL AIR CLEANERS FOR REDUCING INDOOR RADON PROGENY

被引:10
作者
HOPKE, PK
JENSEN, B
MONTASSIER, N
机构
[1] Department of Chemistry, Clarkson University, Potsdam
关键词
D O I
10.1016/0021-8502(94)90090-6
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
Over the past several years, studies have been made of the effectiveness of several kinds of air cleaners in removing radon decay products from indoor air using a recently developed automated, semi-continuous measurement system that can determine the activity-weighted size distributions in occupied homes. Measurements of activity-weighted size distributions and radon concentrations were made every 90 min in a home with a high air exchange rate. A week-long series of measurements was made for the home with no cleaner operating and a similar set of measurements were made for each of the air cleaners. Two different types of air cleaners were tested in this study; filtration units (two different designs from two different manufacturers) and two ion generator/fan systems (identical design NO-RAD systems, but from two different manufacturers). From the measured distributions and a dosimetric model, the effect of the air cleaners on the dose to lung can be estimated. It was found that the filtration units resulted in a median reduction in exposure of 15% and 36% for the two units and corresponding dose reductions of 32% and 53%. The two NO-RAD systems produced 37% and 10% reductions in the median exposure, but the reductions in the median dose were 49% and 46%. Examination of the components of the NO-RAD system operating separately resulted in the fan causing a small dose reduction and the ionizer producing a small dose increase. However, very few size distributions were measured for these separate component studies and a more detailed study of the separate effects of the NO-RAD components is needed.
引用
收藏
页码:395 / 405
页数:11
相关论文
共 22 条
[1]   THE DOSE TO THE TRACHEA AND BRONCHI FROM THE DECAY PRODUCTS OF RADON AND THORON [J].
CHAMBERLAIN, AC ;
DYSON, ED .
BRITISH JOURNAL OF RADIOLOGY, 1956, 29 (342) :317-325
[2]  
Hopke P.K., 1992, INDOOR AIR, V2, P84
[3]   SOME THOUGHTS ON THE UNATTACHED FRACTION OF RADON DECAY PRODUCTS [J].
HOPKE, PK .
HEALTH PHYSICS, 1992, 63 (02) :209-212
[4]  
HOPKE PK, 1991, 1991 P INT S RAD RAD
[5]  
HOPKE PK, 1990, CN409 DIV SCI RES NE
[6]  
JAMES AC, 1993, COMMUNICATION
[7]  
JAMES AC, 1992, INDOOR RADON LUNG CA, P168
[8]   EFFICACY OF AIR CLEANING SYSTEMS IN CONTROLLING INDOOR RADON DECAY PRODUCTS [J].
LI, CS ;
HOPKE, PK .
HEALTH PHYSICS, 1991, 61 (06) :785-797
[9]  
LI CS, 1991, INDOOR AIR, V4, P539
[10]   EM ALGORITHM RECONSTRUCTION OF PARTICLE-SIZE DISTRIBUTIONS FROM DIFFUSION BATTERY DATA [J].
MAHER, EF ;
LAIRD, NM .
JOURNAL OF AEROSOL SCIENCE, 1985, 16 (06) :557-570