3-DIMENSIONAL MOTION ANALYSIS OF AN IMPROVED HEAD IMMOBILIZATION SYSTEM FOR SIMULATION, CT, MRI, AND PET IMAGING

被引:46
作者
THORNTON, AF
TENHAKEN, RK
GERHARDSSON, A
CORRELL, M
机构
[1] Department of Radiation Oncology, University of Michigan Medical Center, Ann Arbor, MI
关键词
HEAD AND NECK; CT; MRI; PET; RADIATION THERAPY; IMMOBILIZATION DEVICE; MOTION ANALYSIS;
D O I
10.1016/0167-8140(91)90120-6
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
A mask/marker immobilization system for the routine radiation therapy treatment of head and neck disease is described, utilizing a commercially available thermoplastic mesh, indexed and mounted to a rigid frame attached to the therapy couch. Designed to permit CT, MRI, and PET diagnostic scans of the patient to be performed in the simulation and treatment position employing the same mask, the system has been tested in order to demonstrate the reproducibility of immobilization throughout a radical course of irradiation. Three-dimensional analysis of patient position over an 8-week course of daily radiation treatment has been performed for nine patients from digitization of anatomic points identified on orthogonal radiographs. Studies employing weekly simulation indicate that patient treatment position movement can be restricted to 2 mm over the course of treatment. This easily constructed system permits rapid mask formation to be performed on the treatment simulator, resulting in an immobilization device comparable to masks produced with vacuum-forming techniques. Details of motion analysis and central axis CT, MRI, and PET markers are offered.
引用
收藏
页码:224 / 228
页数:5
相关论文
共 16 条
  • [1] BUSSE J, 1978, RADIOLOGY, V117, P407
  • [2] Fraass B. A., 1987, USE COMPUTERS RAD TH, P273
  • [3] INTEGRATION OF MAGNETIC-RESONANCE-IMAGING INTO RADIATION-THERAPY TREATMENT PLANNING .1. TECHNICAL CONSIDERATIONS
    FRAASS, BA
    MCSHAN, DL
    DIAZ, RF
    TENHAKEN, RK
    AISEN, A
    GEBARSKI, S
    GLAZER, G
    LICHTER, AS
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1987, 13 (12): : 1897 - 1908
  • [4] THE IMAGING REVOLUTION AND RADIATION ONCOLOGY - USE OF CT, ULTRASOUND, AND NMR FOR LOCALIZATION, TREATMENT PLANNING AND TREATMENT DELIVERY
    GLATSTEIN, E
    LICHTER, AS
    FRAASS, BA
    KELLY, BA
    VANDEGEIJN, J
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1985, 11 (02): : 299 - 314
  • [5] IMMOBILIZATION ERROR - SOME THEORETICAL CONSIDERATIONS
    GOITEIN, M
    BUSSE, J
    [J]. RADIOLOGY, 1975, 117 (02) : 407 - 412
  • [6] LICHTER AS, 1983, COMPUT TOMOGR, P1
  • [7] STEREOTACTIC FRAME FOR NEURORADIOLOGY AND CHARGED-PARTICLE BRAGG PEAK RADIOSURGERY OF INTRACRANIAL DISORDERS
    LYMAN, JT
    PHILLIPS, MH
    FRANKEL, KA
    FABRIKANT, JI
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1989, 16 (06): : 1615 - 1621
  • [8] MCSHAN DL, 1987, COMPUTER ASSISTED RA, P300
  • [9] PLASTIC MATERIAL USED TO OPTIMIZE RADIOTHERAPY OF HEAD AND NECK TUMORS AND THE MAMMARY-CARCINOMA
    NIEWALD, M
    LEHMANN, W
    UHLMANN, U
    SCHNABEL, K
    LEETZ, HK
    [J]. RADIOTHERAPY AND ONCOLOGY, 1988, 11 (01) : 55 - 63
  • [10] PREDICTION OF SURVIVAL IN GLIOMA PATIENTS BY MEANS OF POSITRON EMISSION TOMOGRAPHY
    PATRONAS, NJ
    DICHIRO, G
    KUFTA, C
    BAIRAMIAN, D
    KORNBLITH, PL
    SIMON, R
    LARSON, SM
    [J]. JOURNAL OF NEUROSURGERY, 1985, 62 (06) : 816 - 822