DOPPLER ECHOCARDIOGRAPHIC ASSESSMENT OF FETAL DESCENDING AORTIC AND UMBILICAL BLOOD FLOWS - VALIDATION STUDIES IN FETAL LAMBS

被引:45
作者
SCHMIDT, KG
DITOMMASO, M
SILVERMAN, NH
RUDOLPH, AM
机构
[1] UNIV CALIF SAN FRANCISCO,CARDIOVASC RES INST,ROOM M342A,BOX 0214,SAN FRANCISCO,CA 94143
[2] UNIV CALIF SAN FRANCISCO,DEPT PEDIAT,SAN FRANCISCO,CA 94143
[3] UNIV CALIF SAN FRANCISCO,DEPT OBSTET GYNECOL & REPROD SCI,SAN FRANCISCO,CA 94143
关键词
ECHOCARDIOGRAPHY; FETAL; PRENATAL CARE; FETAL DISEASES;
D O I
10.1161/01.CIR.83.5.1731
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background. Doppler ultrasound has been used to assess abdominal aortic and umbilical blood flows in the human fetus, but the accuracy of this approach has not been demonstrated in an animal model. Methods and Results. We compared abdominal aortic and umbilical blood flows determined by Doppler echocardiography in 12 fetal lambs with invasive flow measurements using radionuclide-labeled microspheres and electromagnetic flow transducers. We varied fetal blood flow from 100 to 950 ml/min in the abdominal aorta and from 130 to 610 ml/min in the umbilical vein. Invasive and Doppler echocardiographic flow measurements correlated well at both sites (y = 68 + 1.02x, r = 0.94, and y = 33 + 1.1x, r = 0.91, respectively). A slight overestimation of flow using the Doppler method may require a correction factor to assess actual flow. The degree of overestimation was not systematically related to measurements taken in smaller vessels or at larger angles of incidence. Conclusions. The present study demonstrates that determination of abdominal aortic and umbilical venous flows by echocardiography and pulsed Doppler ultrasound is feasible. Doppler measurements appear to be suited to serial comparison of actual flow.
引用
收藏
页码:1731 / 1737
页数:7
相关论文
共 36 条
[1]  
ALLAN LD, 1987, BRIT HEART J, V57, P528
[2]   MEASUREMENT OF CARDIAC-OUTPUT WITH AND ORGAN TRAPPING OF RADIOACTIVE MICROSPHERES [J].
ARCHIE, JP ;
FIXLER, DE ;
ULLYOT, DJ ;
HOFFMAN, JIE ;
UTLEY, JR ;
CARLSON, EL .
JOURNAL OF APPLIED PHYSIOLOGY, 1973, 35 (01) :148-154
[3]   INCREASED NUMBER OF MYOCARDIAL BLOOD-FLOW MEASUREMENTS WITH RADIONUCLIDE-LABELED MICROSPHERES [J].
BAER, RW ;
PAYNE, BD ;
VERRIER, ED ;
VLAHAKES, GJ ;
MOLODOWITCH, D ;
UHLIG, PN ;
HOFFMAN, JIE .
AMERICAN JOURNAL OF PHYSIOLOGY, 1984, 246 (03) :H418-H434
[4]   MEASUREMENT OF UMBILICAL BLOOD-FLOW IN FETAL LAMBS IN UTERO [J].
BERMAN, W ;
GOODLIN, RC ;
HEYMANN, MA ;
RUDOLPH, AM .
JOURNAL OF APPLIED PHYSIOLOGY, 1975, 39 (06) :1056-1059
[5]   VELOCITY DISTRIBUTION IN AORTIC FLOW [J].
CLARK, C ;
SCHULTZ, DL .
CARDIOVASCULAR RESEARCH, 1973, 7 (05) :601-613
[6]   DETERMINATION OF PULMONARY TO SYSTEMIC BLOOD-FLOW RATIO IN CHILDREN BY A SIMPLIFIED DOPPLER ECHOCARDIOGRAPHIC METHOD [J].
CLOEZ, JL ;
SCHMIDT, KG ;
BIRK, E ;
SILVERMAN, NH .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1988, 11 (04) :825-830
[7]  
CZAKANSKI P, 1988, AM J CARD IMAG, V2, P142
[8]   FETAL CARDIAC-OUTPUT ESTIMATED BY DOPPLER ECHOCARDIOGRAPHY DURING MIDGESTATION AND LATE GESTATION [J].
DESMEDT, MCH ;
VISSER, GHA ;
MEIJBOOM, EJ .
AMERICAN JOURNAL OF CARDIOLOGY, 1987, 60 (04) :338-342
[9]   MEASUREMENT OF HUMAN-FETAL BLOOD-FLOW [J].
EIKNES, SH ;
BRUBAKK, AO ;
ULSTEIN, MK .
BRITISH MEDICAL JOURNAL, 1980, 280 (6210) :283-284
[10]   ULTRASONIC MEASUREMENT OF HUMAN-FETAL BLOOD-FLOW [J].
EIKNES, SH ;
MARSAL, K ;
BRUBAKK, AO ;
KRISTOFFERSON, K ;
ULSTEIN, M .
JOURNAL OF BIOMEDICAL ENGINEERING, 1982, 4 (01) :28-36