ELECTROSURGERY-INDUCED ENDOTRACHEAL-TUBE IGNITION DURING TRACHEOTOMY

被引:35
作者
ALY, A
MCILWAIN, M
DUNCAVAGE, JA
机构
[1] VANDERBILT UNIV,MED CTR,DEPT OTOLARYNGOL,S-2100,MCN,NASHVILLE,TN 37232
[2] VANDERBILT UNIV,DEPT ORAL SURG,NASHVILLE,TN 37232
关键词
CAUTERY; ELECTROCAUTERY; ELECTROSURGERY; ENDOTRACHEAL TUBE; FIRE; IGNITION; TRACHEOTOMY;
D O I
10.1177/000348949110000105
中图分类号
R76 [耳鼻咽喉科学];
学科分类号
100213 ;
摘要
Electrosurgery was the most common source of ignition for operating room fires prior to the advent of lasers. When combined with volatile anesthetic mixtures, electrosurgery has caused ignition of plastic, rubber, paper, enteric gases, and combustible preparation solutions. We report on an intubated patient whose polyvinyl chloride endotracheal tube ignited during a tracheotomy performed with an electrosurgical unit. The oxygen-rich environment, the polyvinyl chloride tube, and the heat generated by the electrosurgical unit combined to produce a fire. Since otolaryngologists are called upon often to perform tracheotomies on intubated patients, it is imperative that they understand the factors involved in the development of such a fire. This case is presented with an explanation of why this type of fire occurs. A brief review of the literature is included. Different kinds of electrosurgical units, precautions as to their use, and the management of electrosurgery-induced endotracheal tube fires are also discussed.
引用
收藏
页码:31 / 33
页数:3
相关论文
共 6 条
[1]   FIRE FOLLOWING USE OF ELECTROCAUTERY DURING EMERGENCY PERCUTANEOUS TRANS-TRACHEAL VENTILATION [J].
BOWDLE, TA ;
GLENN, M ;
COLSTON, H ;
EISELE, D .
ANESTHESIOLOGY, 1987, 66 (05) :697-698
[2]   A FIRE IN MOUTH - A HAZARD OF USE OF ANTISTATIC ENDOTRACHEAL TUBES [J].
BOYD, CH .
ANAESTHESIA, 1969, 24 (03) :441-&
[3]   HELIUM RETARDS ENDOTRACHEAL-TUBE FIRES FROM CARBON-DIOXIDE LASERS [J].
PASHAYAN, AG ;
GRAVENSTEIN, JS .
ANESTHESIOLOGY, 1985, 62 (03) :274-277
[4]  
PFISTER J, 1985, ELECTROSURGICAL SAFE
[5]   ENDOTRACHEAL-TUBE IGNITION DURING LARYNGEAL SURGERY WITH RESECTOSCOPE [J].
RITA, L ;
SELENY, F .
ANESTHESIOLOGY, 1982, 56 (01) :60-61
[6]   ENDOTRACHEAL-TUBE FIRE IGNITED BY PHARYNGEAL ELECTROCAUTERY [J].
SIMPSON, JI ;
WOLF, GL .
ANESTHESIOLOGY, 1986, 65 (01) :76-77