INTRAVASCULAR ULTRASOUND VERSUS ANGIOGRAPHY FOR MEASUREMENT OD LUMINAL DIAMETERS IN NORMAL AND DISEASED CORONARY-ARTERIES

被引:100
作者
DESCHEERDER, I
DEMAN, F
HERREGODS, MC
WILCZEK, K
BARRIOS, L
RAYMENANTS, E
DESMET, W
DEGEEST, H
PIESSENS, J
机构
[1] Department of Cardiology, University Hospital Gasthuisberg Leuven
关键词
D O I
10.1016/0002-8703(94)90110-4
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Quantitation of coronary luminal diameter with a 20 MHz mechanically rotating intravascular ultrasound (IVUS) catheter was compared with orthogonal-view cineangiography by use of a semiautomated edge-detection algorithm in 48 patients undergoing coronary angioplasty. Quantitative comparison of 196 matched segments was attempted, but in only 174 (88.8%) was a direct comparison of the two techniques possible. In angiographically normal coronary arteries (46 segments) the correlation between the values obtained by quantitative coronary angiography (QCA) and those achieved by IVUS was excellent (r = 0.92, p < 0.0001). For mild stenoses (80 segments) the correlation coefficient was only fair (r = 0.467, p < 0.001). After percutaneous transluminal coronary angioplasty the correlation coefficient between IVUS and QCA data (48 segments) was very weak (r = 0.282, p < 0.05). In conclusion, coronary IVUS is feasible and safe and even for a limited range of coronary arterial narrowing, significant correlations between IVUS and QCA measurements of minimal lumen diameter were found. They were excellent in normal coronary arteries, moderate in mildly diseased arteries, and weak after balloon angioplasty.
引用
收藏
页码:243 / 251
页数:9
相关论文
共 30 条
  • [1] CORONARY-ARTERY NARROWING IN CORONARY HEART-DISEASE - COMPARISON OF CINEANGIOGRAPHIC AND NECROPSY FINDINGS
    ARNETT, EN
    ISNER, JM
    REDWOOD, DR
    KENT, KM
    BAKER, WP
    ACKERSTEIN, H
    ROBERTS, WC
    [J]. ANNALS OF INTERNAL MEDICINE, 1979, 91 (03) : 350 - 356
  • [2] BARTH K, 1989, COMPUTER ASSISTED RA, P220
  • [3] BLANKENHORN DH, 1982, ARCH PATHOL LAB MED, V106, P483
  • [4] DESMET W, UNPUB AM J CARDIOL
  • [5] REPRODUCIBILITY OF CORONARY ARTERIOGRAPHIC READING IN THE CORONARY-ARTERY SURGERY STUDY (CASS)
    FISHER, LD
    JUDKINS, MP
    LESPERANCE, J
    CAMERON, A
    SWAYE, P
    RYAN, T
    MAYNARD, C
    BOURASSA, M
    KENNEDY, JW
    GOSSELIN, A
    KEMP, H
    FAXON, D
    WEXLER, L
    DAVIS, KB
    [J]. CATHETERIZATION AND CARDIOVASCULAR DIAGNOSIS, 1982, 8 (06): : 565 - 575
  • [6] PITFALLS IN THE DETERMINATION OF ABSOLUTE DIMENSIONS USING ANGIOGRAPHIC CATHETERS AS CALIBRATION DEVICES IN QUANTITATIVE ANGIOGRAPHY
    FORTIN, DF
    SPERO, LA
    CUSMA, JT
    SANTORO, L
    BURGESS, R
    BASHORE, TM
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1991, 68 (11) : 1176 - 1182
  • [7] CORONARY ANGIOGRAM INTERPRETATION - INTEROBSERVER VARIABILITY
    GALBRAITH, JE
    MURPHY, ML
    DESOYZA, N
    [J]. JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1978, 240 (19): : 2053 - 2056
  • [8] GRODIN CM, 1974, CIRCULATION, V49, P703
  • [9] Hodgson J M, 1990, Echocardiography, V7, P403, DOI 10.1111/j.1540-8175.1990.tb00381.x
  • [10] HODGSON JM, 1989, INT J CARD IMAGING, V4, P186