OBJECTIVE VERSUS HUMAN OBSERVER DETECTION OF 40-HZ AUDITORY-EVOKED POTENTIALS

被引:7
作者
DOBIE, RA
WILSON, MJ
机构
[1] Otolaryngology-Head, Neck Surgery, University of Texas Health Science Center, 7703 Floyd Curl Drive, San Antonio
关键词
D O I
10.1121/1.411868
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Magnitude-squared coherence (MSC) was used to detect 40-Hz auditory-evoked potentials (AEPs) in a two-alternative forced-choice experiment. MSC performance was found to be better than that of ten human observers. Experienced observers did not perform better than naive observers. In a “yes-no” experiment, observers demonstrated large differences in criterion, with false-positive rates of 2%-20%. Observers also performed better when AEPs were presented in a 50-ms window (two response cycles) than when presented in a 205-ms window (eight response cycles), although total test time was the same; MSC performed equally well in both cases. MSC provides a useful and objective adjunct to visual detection of 40-Hz AEPs. © 1995, Acoustical Society of America. All rights reserved.
引用
收藏
页码:3042 / 3050
页数:9
相关论文
共 23 条
[1]  
AMOS DE, 1963, SCR483 MONOGRAPH
[3]   MIDDLE LATENCY RESPONSE TO A 500-HZ TONE PIP IN NORMAL-HEARING AND IN HEARING-IMPAIRED SUBJECTS [J].
BARAJAS, JJ ;
EXPOSITO, M ;
FERNANDEZ, R ;
MARTIN, LJ .
SCANDINAVIAN AUDIOLOGY, 1988, 17 (01) :21-26
[4]  
BLOSSER AB, 1965, TRACOR65267U TRAC IN
[5]   METHODS FOR DETECTING AUDITORY STEADY-STATE POTENTIALS RECORDED FROM HUMANS [J].
CHAMPLIN, CA .
HEARING RESEARCH, 1992, 58 (01) :63-69
[6]   OBJECTIVE DETECTION OF 40-HZ AUDITORY-EVOKED POTENTIALS - PHASE COHERENCE VS MAGNITUDE-SQUARED COHERENCE [J].
DOBIE, RA ;
WILSON, MJ .
ELECTROENCEPHALOGRAPHY AND CLINICAL NEUROPHYSIOLOGY, 1994, 92 (05) :405-413
[7]   ANALYSIS OF AUDITORY EVOKED-POTENTIALS BY MAGNITUDE-SQUARED COHERENCE [J].
DOBIE, RA ;
WILSON, MJ .
EAR AND HEARING, 1989, 10 (01) :2-13
[8]   OBJECTIVE RESPONSE DETECTION IN THE FREQUENCY-DOMAIN [J].
DOBIE, RA ;
WILSON, MJ .
ELECTROENCEPHALOGRAPHY AND CLINICAL NEUROPHYSIOLOGY, 1993, 88 (06) :516-524
[9]   OBJECTIVE RESPONSE DETECTION [J].
DOBIE, RA .
EAR AND HEARING, 1993, 14 (01) :31-35
[10]   PHASE WEIGHTING - A METHOD TO IMPROVE OBJECTIVE DETECTION OF STEADY-STATE EVOKED-POTENTIALS [J].
DOBIE, RA ;
WILSON, MJ .
HEARING RESEARCH, 1994, 79 (1-2) :94-98