MORTALITY AND MORBIDITY OF REUSING DIALYZERS

被引:58
作者
WING, AJ
BRUNNER, FP
BRYNGER, HOA
CHANTLER, C
DONCKERWOLCKE, RA
GURLAND, HJ
JACOBS, C
SELWOOD, NH
机构
[1] UNIV BASEL,DEPT INNERE MED,CH-4051 BASEL,SWITZERLAND
[2] UNIV GOTHENBURG,DEPT SURG 1,S-40033 GOTHENBURG 33,SWEDEN
[3] GUYS HOSP,EVELINA DEPT PAEDIAT,LONDON SE1 9RT,ENGLAND
[4] STATE UNIV UTRECHT,HET WILHELMINA KINDERZIEKENHUIS,UTRECHT,NETHERLANDS
[5] UNIV MUNICH,KLINIKUM GROSSHADERN,DEPT NEPHROL,MED KLIN I,D-8000 MUNICH 2,FED REP GER
[6] GRP HOSP PITIE SALPETRIERE,PARIS,FRANCE
[7] UK TRANSPLANT,BRISTOL,ENGLAND
关键词
D O I
10.1136/bmj.2.6141.853
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The practice of reusing dialysers in renal units in the UK was surveyed by examining the patient questionnaires returned to the EDTA registration committee for 1976 and by a special questionnaire sent to all UK renal units. Altogether 65-6% of the 1785 patients treated with non-disposable dialysers and 49-6% of the 1109 treated with disposable dialysers reused their equipment. Reuse of dialysers caused some morbidity but no mortality. Most centres where disposable dialysers were used accepted that their reuse was necessary because of financial constraints and was ethically defensible. © 1978, British Medical Journal Publishing Group. All rights reserved.
引用
收藏
页码:853 / 855
页数:3
相关论文
共 6 条
[1]   PRAGMATIC REALITIES IN UREMIA THERAPY [J].
FRIEDMAN, EA ;
DELANO, BG ;
BUTT, KMH .
NEW ENGLAND JOURNAL OF MEDICINE, 1978, 298 (07) :368-371
[2]  
Jacobs C, 1977, Proc Eur Dial Transplant Assoc, V14, P3
[3]  
JUNCOS LI, 1977, DIALYSIS TRANSPLANT, V6, P32
[4]   DIALYSANCE OF MOLECULES OF DIFFERENT SIZE IN REUSED KIIL, AB-GAMBRO, AND RHONE-POULENC DIALYZERS [J].
KRAMER, P ;
TONNIS, J ;
SCHELER, F ;
MATTHAEI, D ;
GO, JG .
BRITISH MEDICAL JOURNAL, 1972, 2 (5809) :320-&
[5]  
SHALDON S, 1976, P EUR DIAL TRANSPLAN, V13, P339
[6]  
1977, HANSARD 1201