ULTRASOUND MEASUREMENT OF WALL THICKNESS IN THE CAROTID-ARTERY - FUNDAMENTAL PRINCIPLES AND DESCRIPTION OF A COMPUTERIZED ANALYZING SYSTEM

被引:445
作者
WENDELHAG, I
GUSTAVSSON, T
SUURKULA, M
BERGLUND, G
WIKSTRAND, J
机构
[1] GOTHENBURG UNIV,SAHLGRENS HOSP,DEPT CLIN PHYSIOL,S-41345 GOTHENBURG,SWEDEN
[2] GOTHENBURG UNIV,SAHLGRENS HOSP,WALLENBERG LAB CARDIOVASC RES,S-41345 GOTHENBURG,SWEDEN
[3] CHALMERS UNIV TECHNOL,DEPT APPL ELECTR,S-41296 GOTHENBURG,SWEDEN
来源
CLINICAL PHYSIOLOGY | 1991年 / 11卷 / 06期
关键词
ATHEROSCLEROSIS; IMAGE ANALYSIS; ULTRASOUND IMAGING;
D O I
10.1111/j.1475-097X.1991.tb00676.x
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
A B-mode [two-dimensional (2D)] image from the carotid artery may be described as containing seven echo zones. The aim of the present work is to discuss how lumen diameter and wall thickness can be measured from these zones, and to review some of the basic principles of ultrasound physics and imaging. Simple experiments were performed to identify the echoes defining intima-lumen interfaces. The results showed that: (1) The intima-media thickness of the near wall cannot be measured in a valid way. (2) The lumen diameter of a blood vessel is defined by the distance from the leading edge of the intima-lumen interface of the near wall (echo zone 3) to the leading edge of the lumen-intima interface of the fall wall (echo zone 5). (3) Previously published studies have validated the intima-media complex of the far wall as the distance from the leading edge of the lumen-intima interface of the far wall to the leading edge of the media-adventitia interface of the far wall (echo zone 7). We suggest that if measurements on the near wall are performed, measurements from the far wall should also be presented separately, and if lumen diameter is measured, that this measurement is carried out according to the leading edge principle. We describe a computerized analysing system for the measurement of wall thickness and plaque area on the carotid and femoral arteries. The system is based on a low-cost PC and a frame grabber board and calculates minimum, maximum and mean values of lumen diameter and wall thickness from a section of the artery.
引用
收藏
页码:565 / 577
页数:13
相关论文
共 20 条
  • [1] [Anonymous], 1989, NEW ENGL J MED, V321, P129
  • [2] BOND MG, 1989, AM J MED, V86, P33
  • [3] BOND MG, 1986, ASSESSMENT ULTRASOUN
  • [4] EPIDEMIOLOGY OF CORONARY HEART-DISEASE - THE FRAMINGHAM-STUDY
    CASTELLI, WP
    [J]. AMERICAN JOURNAL OF MEDICINE, 1984, 76 (2A) : 4 - 12
  • [5] EVALUATION OF A SCORING SYSTEM FOR EXTRACRANIAL CAROTID ATHEROSCLEROSIS EXTENT WITH B-MODE ULTRASOUND
    CROUSE, JR
    HARPOLD, GH
    KAHL, FR
    TOOLE, JF
    MCKINNEY, WM
    [J]. STROKE, 1986, 17 (02) : 270 - 275
  • [6] HELSINKI HEART-STUDY - PRIMARY-PREVENTION TRIAL WITH GEMFIBROZIL IN MIDDLE-AGED MEN WITH DYSLIPIDEMIA - SAFETY OF TREATMENT, CHANGES IN RISK-FACTORS, AND INCIDENCE OF CORONARY HEART-DISEASE
    FRICK, MH
    ELO, O
    HAAPA, K
    HEINONEN, OP
    HEINSALMI, P
    HELO, P
    HUTTUNEN, JK
    KAITANIEMI, P
    KOSKINEN, P
    MANNINEN, V
    MAENPAA, H
    MALKONEN, M
    MANTTARI, M
    NOROLA, S
    PASTERNACK, A
    PIKKARAINEN, J
    ROMO, M
    SJOBLOM, T
    NIKKILA, EA
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 1987, 317 (20) : 1237 - 1245
  • [7] GUSTAVSSON T, 1991, 191 CHALM U TECHN DE
  • [8] THE EFFECTS OF DRUG-TREATMENT FOR HYPERTENSION ON MORBIDITY AND MORTALITY FROM CARDIOVASCULAR-DISEASE - A REVIEW OF RANDOMIZED CONTROLLED TRIALS
    MACMAHON, SW
    CUTLER, JA
    FURBERG, CD
    PAYNE, GH
    [J]. PROGRESS IN CARDIOVASCULAR DISEASES, 1986, 29 (03) : 99 - 118
  • [9] MASLAK SH, 1985, ULTRASOUND ANN, P1
  • [10] MCDICKEN WN, 1976, DIAGNOSTIC ULTRASONI