BORON NEUTRON-CAPTURE ENHANCEMENT OF CF-252 BRACHYTHERAPY

被引:19
作者
BEACH, JL
SCHROY, CB
ASHTARI, M
HARRIS, MR
MARUYAMA, Y
机构
[1] UNIV TEXAS,MD ANDERSON HOSP & TUMOR INST,CTR CANC,DEPT RADIAT PHYS,HOUSTON,TX 77030
[2] LONG ISL JEWISH MED CTR,DEPT RADIOL,NEW HYDE PK,NY
[3] UNIV KENTUCKY,DEPT RADIAT MED,LEXINGTON,KY 40506
来源
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS | 1990年 / 18卷 / 06期
关键词
!sup]252[!/sup]Cf Brain tumor; Boron neutron capture therapy; Brachytherapy;
D O I
10.1016/0360-3016(90)90317-D
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Dosimetric and radiobiological studies were undertaken to investigate the potential enhancement in dose, dose distribution and cell killing effectiveness of 252Cf brachytherapy achievable when boron-10 enriched compounds are incorporated into simulated 252Cf brain implants. Thermal neutron distributions in a human head phantom containing a 252Cf source were measured by gold foil activation and calculated using a 1-dimensional transport code. This information was then used to modify measured event size distributions for 252Cf neutrons to determine the corresponding increase in dose and dose equivalent throughout the phantom. The addition of subtoxic levels of boron-10 to a typical 252Cf implant was found to significantly enhance both the absorbed dose and the high LET event frequency at distances of 3 to 5 cm from individual sources. Some unexpected geometric considerations are discussed. Reduced survival of cultured Chinese hamster cells correlated with the predicted increase in absorbed dose from the capture events with a concentration of about 60 μg 10B per ml in the culture medium. It was found that boron increased a (the "single-hit" parameter of the linear quadratic survival model) by 32% and decreased β (the "double-hit" parameter) by 8%. The αβ ratio increased to 4.34 Gy in the presence of boron, from 3.03 Gy in its absence. This translated to an 8% reduction in californium dose needed to effect 10% cell survival. It is concluded that there is a sufficiently high thermal neutron fluence present during californium brachytherapy for boron neutron capture dose augmentation to be feasible. © 1990.
引用
收藏
页码:1421 / 1427
页数:7
相关论文
共 18 条
[1]  
ARMSTRONG TW, 1973, ORNL4869 REP
[2]  
Brownell G. L., 1978, THERAPY NUCLEAR MED, P205
[3]   DOSE DISTRIBUTIONS AROUND A CALIFORNIUM-252 NEEDLE [J].
COLVETT, RD ;
KRISHNASWAMY, V ;
ROSSI, HH .
PHYSICS IN MEDICINE AND BIOLOGY, 1972, 17 (03) :356-+
[4]   RELATIVE BIOLOGICAL EFFECTIVENESS OF B-10(N, ALPHA)7 LI REACTION IN HELA CELLS [J].
DAVIS, MA ;
LITTLE, JB ;
AYYANGAR, KM ;
REDDY, AR .
RADIATION RESEARCH, 1970, 43 (03) :534-&
[5]   MONTE-CARLO DOSIMETRY CALCULATION FOR BORON NEUTRON-CAPTURE THERAPY IN TREATMENT OF BRAIN TUMORS [J].
DEUTSCH, OL ;
MURRAY, BW .
NUCLEAR TECHNOLOGY, 1975, 26 (03) :320-339
[6]  
ENGLE WW, 1967, US AEC K1693 REP
[7]  
FAIRCHILD RG, 1984, STRAHLENTHER ONKOL, V160, P764
[8]   THE RELATIVE BIOLOGICAL EFFECTIVENESS IN V79 CHINESE-HAMSTER CELLS OF THE NEUTRON-CAPTURE REACTIONS IN BORON AND NITROGEN [J].
GABEL, D ;
FAIRCHILD, RG ;
LARSSON, B ;
BORNER, HG .
RADIATION RESEARCH, 1984, 98 (02) :307-316
[9]   ANALYTICAL CALCULATION OF B-10 DOSAGE IN CELL-NUCLEUS FOR NEUTRON-CAPTURE THERAPY [J].
KOBAYASHI, T ;
KANDA, K .
RADIATION RESEARCH, 1982, 91 (01) :77-94
[10]  
Locher GL, 1936, AM J ROENTGENOL RADI, V36, P1