SIGNAL ANALYSIS OF NONINVASIVE XE-133 CEREBRAL BLOOD-FLOW MEASUREMENTS

被引:4
作者
JAGGI, JL
OBRIST, WD
NOORDERGRAAF, A
机构
[1] UNIV PENN, DEPT NEUROSURG, PHILADELPHIA, PA 19104 USA
[2] UNIV PENN, DEPT BIOENGN, PHILADELPHIA, PA 19104 USA
[3] UNIV PITTSBURGH, DEPT NEUROSURG, PITTSBURGH, PA 15260 USA
关键词
CEREBRAL BLOOD FLOW; SPATIAL RESOLUTION; SENSITIVITY; AIRWAY ARTIFACT; CROSS-TALK; SIGNAL OVERLAP;
D O I
10.1007/BF02367604
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
An anatomical model in conjunction with experimentally determined absorption data provides a framework to simulate signals as obtained from the noninvasive Xenon-133 cerebral blood flow technique. The contribution of individual tissue compartments to the total signal as well as the effect on the computed results were investigated under normal conditions. The introduction of physiological abnormalities into the model allowed the determination of sensitivity of the technique with respect to size, position, and perfusion level of the lesion. In addition, effects of cross-talk between hemispheres and signal overlap of adjacent detectors were quantified. It was found that the change of externally measured blood flow is proportional to the decrement/increment of flow in the lesion. Contrary to earlier reports, the effects of cross-talk and signal overlap were not found to be serious limitations in identifying lesions.
引用
收藏
页码:85 / 95
页数:11
相关论文
共 32 条
  • [1] REMOTE EFFECT OF DEEP-SEATED VASCULAR BRAIN-LESIONS ON CEREBRAL BLOOD-FLOW
    ATTIG, E
    CAPON, A
    DEMEURISSE, G
    VERHAS, M
    [J]. STROKE, 1990, 21 (11) : 1555 - 1561
  • [2] BOLMSJO M, 1984, EUR J NUCL MED, V9, P1, DOI 10.1007/BF00254341
  • [3] EXTRACTION RATIO AND BONE CLEARANCE OF SR85 AS A MEASURE OF EFFECTIVE BONE BLOOD FLOW
    COPP, DH
    SHIM, SS
    [J]. CIRCULATION RESEARCH, 1965, 16 (05) : 461 - &
  • [4] BLOOD-FLOW MEASUREMENTS AND LOOK-THROUGH ARTIFACT IN FOCAL CEREBRAL ISCHEMIA
    DONLEY, RF
    SUNDT, TM
    ANDERSON, RE
    SHARBROUGH, FW
    [J]. STROKE, 1975, 6 (02) : 121 - 131
  • [5] Evans RD, 1955, ATOMIC NUCLEUS, P785
  • [6] GAMBARELLI J, 1977, COMPUTERIZED AXIAL T
  • [7] XENON AND IODINE ENHANCED CEREBRAL CT - A CLOSER LOOK
    GUR, D
    YONAS, H
    WOLFSON, SK
    HERBERT, D
    KENNEDY, WH
    DRAYER, BP
    SHABASON, L
    [J]. STROKE, 1981, 12 (05) : 573 - 578
  • [8] SEX-PHEROMONE OF THE WINTER MOTH, A GEOMETRID WITH UNUSUALLY LOW-TEMPERATURE PRE-COPULATORY RESPONSES
    ROELOFS, WL
    HILL, AS
    LINN, CE
    MEINWALD, J
    JAIN, SC
    HERBERT, HJ
    SMITH, RF
    [J]. SCIENCE, 1982, 217 (4560) : 657 - 659
  • [9] CHANGES OF BLOOD-FLOW IN THE CEREBRAL-CORTEX AFTER SUBCORTICAL ISCHEMIC INFARCTION
    HOJERPEDERSEN, E
    PETERSEN, OF
    [J]. STROKE, 1989, 20 (02) : 211 - 216
  • [10] MEASUREMENT OF MUSCLE BLOOD FLOW IN HUMAN FOREARM WITH RADIOACTIVE KRYPTON + XENON
    HOLZMAN, GB
    ZIERLER, KL
    WAGNER, HN
    RABINOWITZ, D
    IIO, M
    [J]. CIRCULATION, 1964, 30 (01) : 27 - +