X-RAY-IMAGING TEST OF A MU-STRIP SILICON DETECTOR WITH A TRANSPUTER DAQ

被引:4
作者
BENCIVELLI, W
BERTOLUCCI, E
BOTTIGLI, U
CONTI, M
DELGUERRA, A
FANTACCI, ME
GAMBACCINI, M
LAROBINA, M
MARZIANI, M
RANDACCIO, P
ROSSO, V
RUSSO, P
RUSSO, S
SCARLATELLA, A
STEFANINI, A
机构
[1] UNIV PISA,DIPARTIMENTO BIOMED ENGN,I-56100 PISA,ITALY
[2] INFN,PISA,ITALY
[3] UNIV NAPOLI FEDERICO,DIPARTIMENTO SCI FIS,NAPLES,ITALY
[4] UNIV FERRARA,DIPARTIMENTO FIS,I-44100 FERRARA,ITALY
[5] INFN,FERRARA,ITALY
[6] UNIV CAGLIARI,IST FIS MED,I-09100 CAGLIARI,ITALY
[7] INFN,CAGLIARI,ITALY
[8] UNIV NAPOLI FEDERICO II,DIPARTIMENTO INFORMAT & SISTEMIST,NAPLES,ITALY
[9] INFN,NAPLES,ITALY
关键词
D O I
10.1109/23.322942
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
We have developed a TDC+Transputer-based acquisition system to study the X-ray imaging capabilities of a silicon mustrip detector with 100 and 200 mum read-out pitch. This system allows real-time image acquisition and display. We present images obtained with an X-ray mammography tube using sub-millimeter high contrast test objects on a 16*16 channels prototype.
引用
收藏
页码:1522 / 1525
页数:4
相关论文
共 8 条
[1]   DIGITAL IMAGING IN RADIOLOGY - PRELIMINARY-RESULTS OBTAINED WITH A HIGH-SPATIAL-RESOLUTION 2D SILICON DETECTOR [J].
ALFANO, B ;
BANDETTINI, A ;
BENCIVELLI, W ;
BERTOLUCCI, E ;
BOTTIGLI, U ;
CONTI, M ;
DELGUERRA, A ;
FANTACCI, ME ;
GAMBACCINI, M ;
LAROBINA, M ;
MARZIANI, M ;
RANDACCIO, P ;
ROSSO, V ;
RUSSO, P ;
STEFANINI, A .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1993, 40 (04) :987-991
[2]   1ST X-RAY IMAGES WITH A DOUBLE-SIDED MICROSTRIPS SILICON CRYSTAL - A NOVEL DETECTOR FOR DIGITAL RADIOGRAPHY [J].
ALFANO, B ;
BANDETTINI, A ;
BENCIVELLI, W ;
BERTOLUCCI, E ;
BOTTIGLI, U ;
CONTI, M ;
DELGUERRA, A ;
FANTACCI, ME ;
PENKOWSKI, M ;
RANDACCIO, P ;
ROSSO, V ;
RUSSO, P ;
STEFANINI, A .
PHYSICS IN MEDICINE AND BIOLOGY, 1992, 37 (05) :1167-1170
[3]   CHARACTERIZATION OF THE RESPONSE OF A DOUBLE SIDE M-STRIP SILICON DETECTOR TO X-RAYS IN THE DIAGNOSTIC ENERGY-RANGE [J].
BANDETTINI, A ;
BENCIVELLI, W ;
BERTOLUCCI, E ;
BOTTIGLI, U ;
CONTI, M ;
DELGUERRA, A ;
FANTACCI, ME ;
RANDACCIO, P ;
ROSSO, V ;
RUSSO, P ;
STEFANINI, A .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1993, 40 (04) :983-986
[4]  
Batignani G., 1990, Physica Medica, V6, P39
[5]   USE OF EGS4 FOR THE EVALUATION OF THE PERFORMANCE OF A SILICON DETECTOR FOR X-RAY DIGITAL RADIOGRAPHY [J].
BENCIVELLI, W ;
BERTOLUCCI, E ;
BOTTIGLI, U ;
DELGUERRA, A ;
MAZZEI, D ;
MESSINEO, A ;
NELSON, WR ;
RANDACCIO, P ;
ROSSO, V ;
RUSSO, P ;
STEFANINI, A .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1991, 305 (03) :574-580
[6]   A TRANSPUTER-BASED LIST MODE PARALLEL SYSTEM FOR DIGITAL RADIOGRAPHY WITH 2D SILICON DETECTORS [J].
CONTI, M ;
DELGUERRA, A ;
MAZZEO, A ;
MAZZOCCA, N ;
RUSSO, P ;
RUSSO, S ;
SCARLATELLA, A .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1993, 40 (04) :996-1000
[7]  
CONTI M, 1993, PHYS MEDICA, V9, P239
[8]  
CONTI M, 1993, IN PRESS NUCL INSTR