ANCHORAGE OF TIO2-BLASTED, HA-COATED, AND MACHINED IMPLANTS - AN EXPERIMENTAL-STUDY WITH RABBITS

被引:222
作者
GOTFREDSEN, K
WENNERBERG, A
JOHANSSON, C
SKOVGAARD, LT
HJORTINGHANSEN, E
机构
[1] GOTHENBURG UNIV,DEPT HANDICAP RES,BIOMAT GRP,GOTHENBURG,SWEDEN
[2] UNIV COPENHAGEN,FAC HLTH SCI,DEPT STAT,COPENHAGEN,DENMARK
来源
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH | 1995年 / 29卷 / 10期
关键词
D O I
10.1002/jbm.820291009
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The purpose of this study was to evaluate the histometrical and biomechanical anchorage of TiO2-blasted implants and TiO2-blasted implants coated with hydroxyapatite. The control implants were machined. Twenty-six rabbits had a total of 156 implants placed in the proximal part of the tibia. Each rabbit had a machined, a TiO2-blasted, and a TiO2-blasted, HA-coated implant placed in each tibia. After a healing period of 3 and 12 weeks, respectively, the implants placed in the right tibia were used for removal torque test, and the implants placed in the left tibia were used for histomorphometrical measurements. Preoperatively, implants from the same batches were examined topographically with a TopScan 3D system. The TiO2-blasted implants demonstrated significantly higher removal torque values than the machined implants, and they also had a significantly more irregular surface. Furthermore, significantly higher bone-to-implant contact length fractions were measured adjacent to the TiO2-blasted implants in contrast to the machined implants. The advantages of a TiO2-blasted surface were more pronounced after 3 weeks than after 12 weeks. The results demonstrated that it was possible to influence the anchorage of implants by altering the surface structure morphology. The new method with TiO2 blasting on the titanium surface improves the anchorage of implants but is not yet practicable for HA coating. (C) 1995 John Wiley & Sons, Inc.
引用
收藏
页码:1223 / 1231
页数:9
相关论文
共 26 条
[1]  
ADELL R, 1990, International Journal of Oral and Maxillofacial Implants, V5, P347
[2]   OSSEOINTEGRATED TITANIUM IMPLANTS - REQUIREMENTS FOR ENSURING A LONG-LASTING, DIRECT BONE-TO-IMPLANT ANCHORAGE IN MAN [J].
ALBREKTSSON, T ;
BRANEMARK, PI ;
HANSSON, HA ;
LINDSTROM, J .
ACTA ORTHOPAEDICA SCANDINAVICA, 1981, 52 (02) :155-170
[3]  
ALBREKTSSON T, 1989, BRANEMARK OSSEOINTEG, P229
[4]  
BRANEMARK P I, 1969, Scandinavian Journal of Plastic and Reconstructive Surgery, V3, P81
[5]  
BUSER D, 1992, J BIOMED MATER RES, V25, P889
[6]  
Carlsson L, 1988, Int J Oral Maxillofac Implants, V3, P21
[7]  
CARLSSON LV, 1989, THESIS U GOTHENBURG
[8]  
Casella G, 1992, VARIANCE COMPONENTS
[9]   DEPENDENCE OF REMOVAL TORQUE OF A LEG SCREW A SCREW SURFACE AND IMPLANTATION TIME [J].
CLAES, L ;
HUTZSCHENREUTER, P ;
POHLER, O .
ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 1976, 85 (02) :155-159
[10]  
COOK SD, 1991, CLIN ORTHOP RELAT R, V265, P280