USE OF MR IMAGING-COMPATIBLE HALIFAX INTERLAMINAR CLAMPS FOR POSTERIOR CERVICAL FUSION

被引:24
作者
ALDRICH, EF [1 ]
CROW, WN [1 ]
WEBER, PB [1 ]
SPAGNOLIA, TN [1 ]
机构
[1] UNIV TEXAS,MED BRANCH,DIV NEURORADIOL,GALVESTON,TX 77550
关键词
CLAMP; SPINAL FUSION; SPINAL STABILIZATION; MAGNETIC RESONANCE IMAGING;
D O I
10.3171/jns.1991.74.2.0185
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Twenty-one patients requiring posterior cervical fusion were treated with magnetic resonance (MR) imaging-compatible Halifax interlaminar clamps for internal fixation. Various levels were involved: the C1-2 level in eight cases, the C4-5 level in four, the C5-6 level in three, the C6-7 level in three, the C4-6 level in two, and the C5-7 level in one. Bilateral clamps were used in 18 cases and unilateral clamps in three. Autogenous iliac bone grafting was performed in all cases but one. Follow-up periods ranged from 1 to 18 months (average 9.2 months), with no complications or mechanical failures occurring thus far. Follow-up diagnostic studies revealed rigid fixation and fusion in all cases. The MR imaging-compatibility of the clamps allowed excellent follow-up studies with minimal artifact. Because of their ease of use, rigid stabilization, good results, lack of complications, and compatibility with MR imaging, the Halifax interlaminar clamp with bone grafting provides an ideal method for posterior cervical stabilization.
引用
收藏
页码:185 / 189
页数:5
相关论文
共 17 条
[1]  
Alexander E Jr, 1981, Clin Neurosurg, V28, P273
[2]   FIXATION OF FRACTURES OF THE LOWER CERVICAL-SPINE USING METHYLMETHACRYLATE AND WIRE - TECHNIQUE AND RESULTS IN 99 PATIENTS [J].
BRANCH, CL ;
KELLY, DL ;
DAVIS, CH ;
MCWHORTER, JM .
NEUROSURGERY, 1989, 25 (04) :503-513
[3]  
CAHILL DW, 1983, NEUROSURGERY, V13, P1
[4]   USE OF HALIFAX INTERLAMINAR CLAMPS FOR POSTERIOR C1-C2 ARTHRODESIS [J].
CYBULSKI, GR ;
STONE, JL ;
CROWELL, RM ;
RIFAI, MHS ;
GANDHI, Y ;
GLICK, R .
NEUROSURGERY, 1988, 22 (02) :429-431
[5]  
CZERVIONKE LF, 1988, AM J NEURORADIOL, V9, P1149
[6]   CENTRAL SPINAL-CORD INJURY - MAGNETIC-RESONANCE IMAGING CONFIRMATION AND OPERATIVE CONSIDERATIONS [J].
FOX, JL ;
WENER, L ;
DRENNAN, DC ;
MANZ, HJ ;
WON, DJ ;
ALMEFTY, O .
NEUROSURGERY, 1988, 22 (02) :340-347
[7]  
Geisler F H, 1988, Md Med J, V37, P525
[8]   TITANIUM WIRE INTERNAL-FIXATION FOR STABILIZATION OF INJURY OF THE CERVICAL-SPINE - CLINICAL-RESULTS AND POSTOPERATIVE MAGNETIC-RESONANCE IMAGING OF THE SPINAL-CORD [J].
GEISLER, FH ;
MIRVIS, SE ;
ZREBEET, H ;
JOSLYN, JN .
NEUROSURGERY, 1989, 25 (03) :356-362
[9]   COMPLICATIONS OF SUBLAMINAR WIRING [J].
GEREMIA, GK ;
KIM, KS ;
CERULLO, L ;
CALENOFF, L .
SURGICAL NEUROLOGY, 1985, 23 (06) :629-634
[10]   POSTERIOR STABILIZATION WITH AN INTERLAMINAR CLAMP IN CERVICAL INJURIES - TECHNICAL NOTE AND REVIEW OF THE LONG-TERM EXPERIENCE WITH THE METHOD [J].
HOLNESS, RO ;
HUESTIS, WS ;
HOWES, WJ ;
LANGILLE, RA .
NEUROSURGERY, 1984, 14 (03) :318-322