ON THE EVALUATION OF THE CORNEAL EPITHELIAL SURFACE BY SCANNING ELECTRON-MICROSCOPY

被引:18
作者
DOUGHTY, MJ
机构
[1] School of Optometry, University of Waterloo, Waterloo, ON
关键词
Contact lens wear; Corneal epithelium; Preservatives; Rabbit; Scanning electron microscopy;
D O I
10.1097/00006324-199010000-00001
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
A comprehensive and objective survey is presented of the use of the scanning electron microscope from 1967 to 1989 to assess the characteristics of the corneal epithelial surface in the rabbit and other vertebrates. The technique shows the corneal surface as a mosaic of cells that are very heterogeneous with respect to character (light, medium, and dark electron reflexes), size (small, medium, and large), and shape (angular or rounded), yet the numerous published micrographs of normal corneas show substantial differences. The reasons for these differences are discussed using examples of 50 to 15,000 × magnification micrographs of rabbit corneas within the context of the basic principles of glutaraldehyde-based fixation of biological tissues for electron microscopy. The qualitative similarities between the scanning electron microscope image and the in vivo reflected light microscope (specular microscopy and CONFOCAL microscopy) image are reviewed and discussed. © 1990 American Academy of Optometry.
引用
收藏
页码:735 / 756
页数:22
相关论文
共 196 条
[1]  
Holly F.J., The Preocular Tear Film in Health, Disease and Contact Lens Wear, (1986)
[2]  
Larke J., The Eye in Contact Lens Wear, (1985)
[3]  
Hamano H., Kaufman H.E., The Physiology of the Cornea and Contact Lens Applications, (1987)
[4]  
Jones L.T., Marquis M.M., Vincent J.T., Lacrimal function, Am J Ophthalmol, 73, pp. 658-659, (1972)
[5]  
Guillon M., Lydon D., Tear layer thickness characteristics of rigid gas permeable lenses, Am J Optom Physiol Opt, 63, pp. 527-535, (1986)
[6]  
Poise K.A., Etiology of corneal sensitivity changes accompanying contact lens wear, Invest Ophthalmol Vis Sci, 17, pp. 1202-1206, (1978)
[7]  
Norn M.S., Micropunctate fluorescein staining of the cornea, Acta Ophthalmol (Kbh), 48, pp. 108-118, (1970)
[8]  
Feldman F., Wood M.M., Evaluation of the Schirmer tear test, Can J Ophthalmol, 14, pp. 257-259, (1979)
[9]  
Patel S., Bevan R., Farrell J.C., Diurnal variation in pre-corneal tear film stability, Am J Optom Physiol Opt, 65, pp. 151-154, (1988)
[10]  
McFarland J.L., Laing R.A., Oak S.S., Specular microscopy of corneal epithelium, Arch Ophthalmol, 101, pp. 451-454, (1983)