BREMSSTRAHLUNG REVIEW - AN ANALYSIS OF THE SCHIFF SPECTRUM

被引:37
作者
DESOBRY, GE
BOYER, AL
机构
[1] Department of Radiation Physics, University of Texas, M. D. Anderson Cancer Center, Houston
关键词
BREMSSTRAHLUNG; SCHIFF SPECTRUM;
D O I
10.1118/1.596653
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
A concise approximate formula computed by Schiff for the intensity spectrum of bremsstrahlung photons has been a valuable starting point for many medical physics applications, including the Task Group 21 protocols. This paper provides a brief review of the literature related to determination of the bremsstrahlung spectrum and to the Schiff formula in particular. It describes the approximations Schiff made to obtain this formula, including the Born approximation, an exponential nuclear screening potential, the infinite-mass nucleus approximation, and the "extreme relativistic" approximation. A derivation of a more exact formula that avoids the last of these approximations is presented. This provides a check on the accuracy of the Schiff spectrum for linear accelerator energies used clinically. Comparisons with the Schiff thin-target result are presented. A thick-target bremsstrahlung spectrum is calculated and compared with the forward spectrum obtained from Monte Carlo simulations of the x-ray production in two linear accelerator treatment heads.
引用
收藏
页码:497 / 505
页数:9
相关论文
共 45 条
[1]   THE ABSORPTION OF HIGH ENERGY QUANTA .1. [J].
ADAMS, GD .
PHYSICAL REVIEW, 1948, 74 (11) :1707-1711
[2]  
[Anonymous], 1983, MED PHYS, V10, P741
[3]  
[Anonymous], [No title captured]
[4]   A LAPLACE TRANSFORM PAIR MODEL FOR SPECTRAL RECONSTRUCTION [J].
ARCHER, BR ;
WAGNER, LK .
MEDICAL PHYSICS, 1982, 9 (06) :844-847
[5]   ANALYSIS OF ERRORS IN SPECTRAL RECONSTRUCTION WITH A LAPLACE TRANSFORM PAIR MODEL [J].
ARCHER, BR ;
WAGNER, LK ;
JOHNSTON, DA ;
ALMOND, PR ;
BUSHONG, SC .
PHYSICS IN MEDICINE AND BIOLOGY, 1985, 30 (05) :411-418
[6]   APPLICATION OF A LAPLACE TRANSFORM PAIR MODEL FOR HIGH-ENERGY X-RAY SPECTRAL RECONSTRUCTION [J].
ARCHER, BR ;
ALMOND, PR ;
WAGNER, LK .
MEDICAL PHYSICS, 1985, 12 (05) :630-633
[7]   A STUDY OF EFFECTIVE ATTENUATION COEFFICIENT FOR CALCULATING TISSUE COMPENSATOR THICKNESS [J].
BAGNE, FR ;
SAMSAMI, N ;
HOKE, SW ;
BRONN, DG .
MEDICAL PHYSICS, 1990, 17 (01) :117-121
[8]   X-RAY SPECTRA FROM ACCELERATORS IN RANGE 2 TO 6 MEV [J].
BENTLEY, RE ;
JONES, JC ;
LILLICRAP, SC .
PHYSICS IN MEDICINE AND BIOLOGY, 1967, 12 (03) :301-+
[9]   BREMSSTRAHLUNG AND PHOTONEUTRONS FROM THICK TUNGSTEN AND TANTALUM TARGETS [J].
BERGER, MJ ;
SELTZER, SM .
PHYSICAL REVIEW C, 1970, 2 (02) :621-+
[10]   On the stopping of fast particles and on the creation of positive electrons [J].
Bethe, H ;
Heitler, W .
PROCEEDINGS OF THE ROYAL SOCIETY OF LONDON SERIES A-CONTAINING PAPERS OF A MATHEMATICAL AND PHYSICAL CHARACTER, 1934, 146 (A856) :0083-0112