HEAD HOLDER FOR PET, CT, AND MR STUDIES

被引:43
作者
BETTINARDI, V
SCARDAONI, R
GILARDI, MC
RIZZO, G
PERANI, D
PAULESU, E
STRIANO, G
TRIULZI, F
FAZIO, F
机构
[1] UNIV MILAN,I-20122 MILAN,ITALY
[2] CNR,I-20133 MILAN,ITALY
关键词
COMPUTED TOMOGRAPHY; APPARATUS AND EQUIPMENT; EMISSION COMPUTED TOMOGRAPHY; MAGNETIC RESONANCE IMAGING;
D O I
10.1097/00004728-199109000-00034
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
A new head holder for the fixation and repositioning of the patient head in PET, CT, and MR scanners has been designed and tested. With this device, a bidimensional correlation between functional and anatomical brain images can also be obtained. Head fixation and repositioning are achieved using the patient's dental morphology as an anatomical reference. With a dentistic material, a mold of the patient's teeth is obtained in a few minutes. The molding substance rests on a plastic support, fixed to the head holder. Each time the patient undergoes a new study, his/her personal mold is used, ensuring accurate head repositioning. External markers fixed on the head holder (made visible in lateral PET and CT projection images, midsagittal MR images, and also on the axial images) make it possible to record and recognize the angular orientation and the position of the brain in the three-dimensional space, to correlate images of the same patient obtained with different neuroimaging modalities, and to accurately reposition patients for follow-up studies. The head holder was tested on several subjects. Fixation and repositioning accuracy of within 2.5 mm were achieved in the three-dimensional space. Orientation accuracy was 1-degrees.
引用
收藏
页码:886 / 892
页数:7
相关论文
共 29 条
  • [1] HEAD FIXATION DEVICE FOR REPRODUCIBLE POSITION ALIGNMENT IN TRANSMISSION CT AND POSITRON EMISSION TOMOGRAPHY
    BERGSTROM, M
    BOETHIUS, J
    ERIKSSON, L
    GREITZ, T
    RIBBE, T
    WIDEN, L
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1981, 5 (01) : 136 - 141
  • [2] AN ADAPTER TO THE LEKSELL STEREOTAXIC INSTRUMENT FOR DIGITAL COORDINATE DETERMINATION IN RADIOGRAPHY
    BERGSTROM, M
    GREITZ, T
    RIBBE, T
    [J]. NEURORADIOLOGY, 1987, 29 (06) : 585 - 587
  • [3] SPECIFICATION AND SELECTION OF REGIONS OF INTEREST (ROIS) IN A COMPUTERIZED BRAIN ATLAS
    BOHM, C
    GREITZ, T
    SEITZ, R
    ERIKSSON, L
    [J]. JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 1991, 11 (02) : A64 - A68
  • [4] AN INEXPENSIVE VIDEO PATIENT REPOSITIONING SYSTEM FOR USE WITH TRANSMISSION AND EMISSION COMPUTED TOMOGRAPHS
    CONTI, J
    DECK, MDF
    ROTTENBERG, DA
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1982, 6 (02) : 417 - 421
  • [5] ANATOMICAL-FUNCTIONAL CORRELATION USING AN ADJUSTABLE MRI-BASED REGION OF INTEREST ATLAS WITH POSITRON EMISSION TOMOGRAPHY
    EVANS, AC
    BEIL, C
    MARRETT, S
    THOMPSON, CJ
    HAKIM, A
    [J]. JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 1988, 8 (04) : 513 - 530
  • [6] EVANS AC, 1989, P SOC PHOTO-OPT INS, V1092, P264
  • [7] A STEREOTACTIC METHOD OF ANATOMICAL LOCALIZATION FOR POSITRON EMISSION TOMOGRAPHY
    FOX, PT
    PERLMUTTER, JS
    RAICHLE, ME
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1985, 9 (01) : 141 - 153
  • [8] LOCALIZATION IN PET IMAGES - DIRECT FITTING OF THE INTERCOMMISSURAL (AC-PC) LINE
    FRISTON, KJ
    PASSINGHAM, RE
    NUTT, JG
    HEATHER, JD
    SAWLE, GV
    FRACKOWIAK, RSJ
    [J]. JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 1989, 9 (05) : 690 - 695
  • [9] A NEW HEADHOLDER FOR PET, CT, AND NMR IMAGING
    KEARFOTT, KJ
    ROTTENBERG, DA
    KNOWLES, RJR
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1984, 8 (06) : 1217 - 1220
  • [10] MATSUI T, 1978, ATLAS HUMAN BRAIN CO