RETROSPECTIVE EVALUATION OF FLOW-CYTOMETRY AS A PLATELET CROSS-MATCHING PROCEDURE

被引:11
作者
GATES, K
MACPHERSON, BR
机构
[1] UNIV VERMONT,COLL MED,DEPT PATHOL,BURLINGTON,VT 05405
[2] UNIV VERMONT,COLL ALLIED HLTH SCI,DEPT MED TECHNOL,BURLINGTON,VT
来源
CYTOMETRY | 1994年 / 18卷 / 03期
关键词
BLOOD PLATELETS; PLATELET TRANSFUSIONS; PLATELET ANTIBODY TESTING;
D O I
10.1002/cyto.990180303
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
We performed a retrospective analysis of flow cytometry as a platelet crossmatching procedure. Sera from 17 alloimmunized refractory patients were tested against 32 donor platelets, which had been stored as platelet-rich plasma for up to 36 months. Overall, 14/32 (44%) crossmatches were positive. The mean 1 h posttransfusion corrected count increments (CCls) were 9,195 and 2,269 for a negative and a positive crossmatch, respectively. The predictive value of a positive crossmatch was 86%, whereas the predictive value of a negative crossmatch was 56%. When samples with low background fluorescence or with high panel-reactive antibody (PRA) levels were evaluated separately, the accuracy of the crossmatch improved from 69% to 80%. When compared to the platelet adhesion immunofluorescence test (PAIFT) and the standard and antiglobulin-enhanced lymphocytotoxicity tests for the detection of HLA antibodies, flow cytometry appeared to be more sensitive. We conclude that flow cytometry is a useful technique for platelet crossmatching, particularly for alloimmunized patients for whom HLA compatible platelets may not be readily available. (C) 1994 Wiley-Liss, Inc.
引用
收藏
页码:123 / 128
页数:6
相关论文
共 27 条
[1]   A SIMPLE MICRO CYTOTOXICITY TEST [J].
AMOS, DB ;
BASHIR, H ;
BOYLE, W ;
MACQUEEN, M ;
TIILIKAINEN, A .
TRANSPLANTATION, 1969, 7 (03) :220-+
[2]   THE DETECTION OF PLATELET ANTIBODIES USING A MODIFIED PLATELET IMMUNOFLUORESCENCE TEST [J].
BOISVERT, A ;
MACPHERSON, BR .
AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 1983, 80 (06) :839-843
[3]  
BRAND A, 1978, BLOOD, V51, P781
[4]   PREDICTIVE VALUE OF ENZYME-LINKED IMMUNOASSAY PLATELET CROSS-MATCHING FOR TRANSFUSION OF PLATELET CONCENTRATES TO ALLOIMMUNIZED RECIPIENTS [J].
BRUBAKER, DB ;
DUKE, JC ;
ROMINE, M .
AMERICAN JOURNAL OF HEMATOLOGY, 1987, 24 (04) :375-387
[5]   PLATELET TRANSFUSION FROM DONORS MISMATCHED FOR CROSSREACTIVE HLA ANTIGENS [J].
DAHLKE, MB ;
WEISS, KL .
TRANSFUSION, 1984, 24 (04) :299-302
[6]   SUCCESSFUL TRANSFUSION OF PLATELETS MISMATCHED FOR HLA ANTIGENS TO ALLOIMMUNIZED THROMBOCYTOPENIC PATIENTS [J].
DUQUESNOY, RJ ;
FILIP, DJ ;
RODEY, GE ;
RIMM, AA ;
ASTER, RH .
AMERICAN JOURNAL OF HEMATOLOGY, 1977, 2 (03) :219-226
[7]   PROSPECTIVE PLATELET CROSSMATCHING FOR SELECTION OF COMPATIBLE RANDOM DONORS [J].
FREEDMAN, J ;
HOOI, C ;
GARVEY, MB .
BRITISH JOURNAL OF HAEMATOLOGY, 1984, 56 (01) :9-18
[8]  
FRIEDBERG RC, 1993, BLOOD, V81, P3428
[9]   ANTIGENIC SPECIFICITY OF ANTIBODY REACTIVE IN THE ANTIGLOBULIN-AUGMENTED LYMPHOCYTOTOXICITY TEST [J].
FULLER, TC ;
PHELAN, D ;
GEBEL, HM ;
RODEY, GE .
TRANSPLANTATION, 1982, 34 (01) :24-29
[10]  
HEAL JM, 1987, BLOOD, V70, P23