Application of the Raman Heterodyne Technique for the Detection of EPR and ENDOR

被引:13
作者
Manson, N. B. [1 ]
Fisk, P. T. H. [1 ]
He, X. -F. [1 ]
机构
[1] Australian Natl Univ, Res Sch Phys Sci & Engn, Laser Phys Ctr, Canberra, ACT 2601, Australia
关键词
D O I
10.1007/BF03166169
中图分类号
O64 [物理化学(理论化学)、化学物理学]; O56 [分子物理学、原子物理学];
学科分类号
070203 ; 070304 ; 081704 ; 1406 ;
摘要
Raman heterodyne detection is a coherent optical-RF double resonance technique where the optical and RF fields induce coherence within a three level system and a resultant Raman field is measured using heterodyne detection. This approach has been used previously to detect NMR and more recently EPR. In this paper the parameters that affect the amplitude and signal to noise ratio of the Raman heterodyne signals are considered. The power levels in relation to the oscillator strength and dephasing times, the amplitude and spectrum of the laser frequency jitter in relation to the optical homogeneous linewidths and holeburning rates, and the sample properties such as absorption strength and optical quality, are all factors that affect the Raman signal. The presentation is focused on the Raman heterodyne detected EPR of the nitrogen-vacancy pair centre in diamond making comparisons with Raman heterodyne detected NMR signals obtained for rare earth ion systems. RF-RF double resonance studies, RF holeburning and ENDOR, which give information about the hyperfine levels are also reported for the nitrogen-vacancy centre. The resonance frequencies are in agreement with those predicted from the spin Hamiltonian. The factors affecting the lineshapes and relative intensities of the double resonance signals are discussed.
引用
收藏
页码:999 / 1019
页数:21
相关论文
共 24 条
[1]  
Abramowitz M., 1965, HDB MATH FUNCTIONS
[2]  
Bloch P.D., 1985, J PHYS-PARIS, V7, P523
[3]   LUMINESCENCE DECAY TIME OF THE 1.945 EV CENTER IN TYPE IB DIAMOND [J].
COLLINS, AT ;
THOMAZ, MF ;
JORGE, MIB .
JOURNAL OF PHYSICS C-SOLID STATE PHYSICS, 1983, 16 (11) :2177-2181
[4]   OPTICAL STUDIES OF 1.945 EV VIBRONIC BAND IN DIAMOND [J].
DAVIES, G ;
HAMER, MF .
PROCEEDINGS OF THE ROYAL SOCIETY OF LONDON SERIES A-MATHEMATICAL AND PHYSICAL SCIENCES, 1976, 348 (1653) :285-298
[5]  
Davies G, 1977, CHEM PHYS CARBON, V13, P2
[7]   A LOW-MAGNETIC-FIELD RAMAN HETERODYNE STUDY OF THE VANVLECK PARAMAGNET YALO3-EU-3+ [J].
ERICKSON, LE .
JOURNAL OF PHYSICS C-SOLID STATE PHYSICS, 1987, 20 (02) :291-298
[8]   OPTICAL-PUMPING EFFECTS ON RAMAN-HETERODYNE-DETECTED MULTIPULSE RF NUCLEAR-SPIN-ECHO DECAY [J].
ERICKSON, LE .
PHYSICAL REVIEW B, 1990, 42 (07) :3789-3797
[9]   NMR MEASUREMENT OF AN ION IN AN EXCITED-STATE BY INDIRECT OPTICAL-DETECTION - A 1G4 LEVEL OF LIYF4-PR3+ [J].
ERICKSON, LE .
PHYSICAL REVIEW B, 1985, 32 (01) :1-5
[10]   ANOMALOUS LINESHAPES IN RAMAN HETERODYNE DETECTED EPR [J].
FISK, PTH ;
HE, XF ;
HOLLIDAY, K ;
MANSON, NB .
JOURNAL OF LUMINESCENCE, 1990, 45 (1-6) :26-28