AUTOMATIC CONTINUOUS-FLOW DETERMINATION OF SULFITE IN THE PRESENCE OF A HIGH-CONCENTRATION OF THIOSULFATE

被引:13
作者
COSANO, JS [1 ]
DECASTRO, MDL [1 ]
VALCARCEL, M [1 ]
机构
[1] UNIV CORDOBA,FAC SCI,DEPT ANALYT CHEM,E-14004 CORDOBA,SPAIN
关键词
FLOW SYSTEM; SPECTROPHOTOMETRY; SULFITE; ONLINE DILUTION; THIOSULPHATE/SULPHITE RATIOS;
D O I
10.1016/0003-2670(94)00451-Q
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A spectrophotometric method for the determination of sulphite in the presence of up to 200-fold of thiosulphate is proposed. The derivatizing reaction, which is based on the decoloration of p-rosaniline in neutral or slightly basic medium, is developed in an unsegmented flow system. A linear calibration range between 1 and 20 mu g ml(-1) was obtained, with a relative standard deviation of 1.5% and sampling frequency of 40 h(-1). The method has been applied to the determination of the analyte in samples from an ammonium thiosulphate production plant, where the concentration of sulphite is the quality parameter. The concentration of sulphite and thiosulphate in these samples [0.2-1.0% and 50-60% (w/w), respectively] makes necessary a 1:1000 on-line dilution, and the use of peak-width measurements. In these working conditions the linear range was 2.7-20.0 g l(-1) and the R.S.D. values ranged between 1.3 and 2.8%, depending on the constant absorbance value selected for measurement. The sampling frequency was 8 h(-1).
引用
收藏
页码:269 / 274
页数:6
相关论文
共 22 条
[1]  
ABDELLATIF MS, 1989, ANAL LETT, V22, P1355
[2]   FLOW-INJECTION CHEMILUMINESCENCE DETERMINATION OF SULFITE [J].
ALTAMRAH, SA ;
TOWNSHEND, A ;
WHEATLEY, AR .
ANALYST, 1987, 112 (06) :883-886
[3]   DETERMINATION OF SULFITE AND HYDROGEN-PEROXIDE IN PHARMACEUTICAL MATRICES VIA CLASSICAL SPECTROPHOTOMETRY AND FLOW-INJECTION [J].
BROWN, DS ;
JENKE, DR .
ANALYST, 1987, 112 (06) :899-902
[4]   DETERMINATION OF SULFUR ANIONS BY FLOW-INJECTION WITH A MOLECULAR-EMISSION CAVITY DETECTOR [J].
BURGUERA, JL ;
BURGUERA, M .
ANALYTICA CHIMICA ACTA, 1984, 157 (01) :177-181
[5]   IODIMETRIC AND BROMIMETRIC FLOW-INJECTION AMPEROMETRIC METHODS OF DETERMINING SULFITE IN WHICH IODINE OR BROMINE IS MONITORED AT A GLASSY-CARBON ELECTRODE [J].
FOGG, AG ;
GUTA, CW ;
CHAMSI, AY .
ANALYST, 1987, 112 (03) :253-258
[6]   ELIMINATION OF DOUBLE PEAKS IN THE IODIMETRIC FLOW-INJECTION VISIBLE SPECTROPHOTOMETRIC DETERMINATION OF SULFITE USING A SINGLE-CHANNEL MANIFOLD [J].
FOGG, AG ;
WANG, XW ;
TYSON, JF .
ANALYST, 1990, 115 (03) :305-307
[7]  
GRANADOS M, 1987, ANAL CHIM ACTA, V192, P445
[8]   INDIRECT DETERMINATION OF HYDROGEN-PEROXIDE BY ION CHROMATOGRAPHY [J].
JENKE, DR .
JOURNAL OF CHROMATOGRAPHIC SCIENCE, 1986, 24 (08) :352-355
[9]   APPLICATION OF INDIRECT PHOTOMETRIC CHROMATOGRAPHY TO PHARMACEUTICAL ANALYSIS [J].
JENKE, DR ;
RAGHAVAN, N .
JOURNAL OF CHROMATOGRAPHIC SCIENCE, 1985, 23 (02) :75-80
[10]  
LAZARO F, 1987, ANALUSIS, V15, P183