A NOVEL ENDOTOXIN-SPECIFIC ASSAY BY TURBIDIMETRY WITH LIMULUS AMEBOCYTE LYSATE CONTAINING BETA-GLUCAN

被引:38
作者
KAMBAYASHI, J [1 ]
YOKOTA, M [1 ]
SAKON, M [1 ]
SHIBA, E [1 ]
KAWASAKI, T [1 ]
MORI, T [1 ]
TSUCHIYA, M [1 ]
OISHI, H [1 ]
MATSUURA, S [1 ]
机构
[1] WAKO PURE CHEM IND,OSAKA,JAPAN
来源
JOURNAL OF BIOCHEMICAL AND BIOPHYSICAL METHODS | 1991年 / 22卷 / 02期
关键词
ENDOTOXIN; TURBIDIMETRY; AMEBOCYTE LYSATE; BETA-GLUCAN; LIMULUS;
D O I
10.1016/0165-022X(91)90022-O
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The gelation of standard Limulus amoebocyte lysate (LAL) is triggered by the addition of a small amount of beta-glucan (1-1000 ng/ml plasma), but in the presence of an excessive amount of beta-glucan (1 mg/ml plasma), the gelation becomes insensitive to beta-glucan. Utilizing this property, a method to determine quantitatively the amount of endotoxin circulating in humans was developed. When a modified LAL, or LAL-ES, which contains an excessive amount of CM-curdlan as beta-glucan, was used for the assay, a linear relation in the logarithmic scales was obtained between the gelation time measured by the turbidimetry (min) and the concentration of endotoxin. This relation was not affected by a considerable amount of beta-glucan (100 ng/ml). The sensitivity of the endotoxin assay was estimated to be as low as 3 pg/ml. The following aspects of the method were found by clinical application to normal and febrile subjects. (1) Using both LAL and LAL-ES, it was possible to distinguish the effect of endotoxin from that of beta-glucan in plasma, i.e., bacterial sepsis from fungal sepsis. (2) The amount of circulating endotoxin determined by the present method showed good correlation to those obtained by chromogenic assay using modified LAL devoid of Factor G which could be activated by beta-glucan.
引用
收藏
页码:93 / 100
页数:8
相关论文
共 9 条
[1]  
LEVIN J, 1968, THROMB DIATH HAEMOST, V19, P186
[2]   A NEW (1-]3)-BETA-D-GLUCAN-MEDIATED COAGULATION PATHWAY FOUND IN LIMULUS AMEBOCYTES [J].
MORITA, T ;
TANAKA, S ;
NAKAMURA, T ;
IWANAGA, S .
FEBS LETTERS, 1981, 129 (02) :318-321
[3]   A NEW CHROMOGENIC ENDOTOXIN-SPECIFIC ASSAY USING RECOMBINED LIMULUS COAGULATION ENZYMES AND ITS CLINICAL-APPLICATIONS [J].
OBAYASHI, T ;
TAMURA, H ;
TANAKA, S ;
OHKI, M ;
TAKAHASHI, S ;
ARAI, M ;
MASUDA, M ;
KAWAI, T .
CLINICA CHIMICA ACTA, 1985, 149 (01) :55-65
[4]  
OISHI H, 1985, Journal of Parenteral Science and Technology, V39, P194
[5]  
STEWARD M, 1990, ANTIGEN RECOGNITION, P75
[6]  
STEWART G. A., 1963, PROGR MED CHEM, V3, P187, DOI 10.1016/S0079-6468(08)70119-X
[7]  
TACHIYAMA G, 1988, JAP J SURG, V18, P397
[8]  
TSUCHIYA M, 1989, NIHON SAIKINGAKU ZAS, V44, P398
[9]   A SIMPLE TURBIDIMETRIC TIME ASSAY OF THE ENDOTOXIN IN PLASMA [J].
YOKOTA, M ;
KAMBAYASHI, J ;
TANAKA, T ;
TSUJINAKA, T ;
SAKON, M ;
MORI, T .
JOURNAL OF BIOCHEMICAL AND BIOPHYSICAL METHODS, 1989, 18 (02) :97-104