MRI-PET REGISTRATION WITH AUTOMATED ALGORITHM

被引:1344
作者
WOODS, RP
MAZZIOTTA, JC
CHERRY, SR
机构
[1] UNIV CALIF LOS ANGELES,SCH MED,DEPT PHARMACOL,DIV NUCL MED,LOS ANGELES,CA 90024
[2] UNIV CALIF LOS ANGELES,SCH MED,NEUROPSYCHIAT INST LAB NUCL MED,DEPT NEUROL,DIV BRAIN MAPPING,LOS ANGELES,CA 90024
关键词
EMISSION COMPUTED TOMOGRAPHY; COREGISTRATION; IMAGE REGISTRATION; MAGNETIC RESONANCE IMAGING;
D O I
10.1097/00004728-199307000-00004
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: We have Previously reported an automated method for within-modality (e.g., PET-to-PET) image alignment. We now describe modifications to this method that allow for cross-modality registration of MRI and PET brain images obtained from a single subject. Methods: This method does not require fiducial markers and the user is not required to identify common structures on the two image sets. To align the images, the algorithm seeks to minimize the standard deviation of the PET pixel values that correspond to each MRI pixel value. The MR images must be edited to exclude nonbrain regions prior to using the algorithm. Results and Conclusion: The method has been validated quantitatively using data from patients with stereotaxic fiducial markers rigidly fixed in the skull. Maximal three-dimensional errors of <3 mm and mean three-dimensional errors of <2 mm were measured. Computation time on a SPARCstation IPX varies from 3 to 9 min to align MR image sets with [F-18]fluorodeoxyglucose PET images. The MR alignment with noisy (H2O)-O-15 PET images typically requires 20-30 min.
引用
收藏
页码:536 / 546
页数:11
相关论文
共 9 条
[1]  
ALPERT NM, 1990, J NUCL MED, V31, P1717
[2]   PET SYSTEM CALIBRATIONS AND CORRECTIONS FOR QUANTITATIVE AND SPATIALLY ACCURATE IMAGES [J].
HOFFMAN, EJ ;
GUERRERO, TM ;
GERMANO, G ;
DIGBY, WM ;
DAHLBOM, M .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1989, 36 (01) :1108-1112
[3]   ACCURATE 3-DIMENSIONAL REGISTRATION OF CT, PET, AND OR MR IMAGES OF THE BRAIN [J].
PELIZZARI, CA ;
CHEN, GTY ;
SPELBRING, DR ;
WEICHSELBAUM, RR ;
CHEN, CT .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1989, 13 (01) :20-26
[4]  
Press W.H., 1994, NUMERICAL RECIPES C, V2nd ed.
[5]  
ROBB R A, 1991, Australasian Physical and Engineering Sciences in Medicine, V14, P9
[6]  
ROBINSON EA, 1981, LEAST SQUARES REGRES
[7]   IMPLEMENTATION AND EVALUATION OF A CALCULATED ATTENUATION CORRECTION FOR PET [J].
SIEGEL, S ;
DAHLBOM, M .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1992, 39 (04) :1117-1121
[8]   RAPID AUTOMATED ALGORITHM FOR ALIGNING AND RESLICING PET IMAGES [J].
WOODS, RP ;
CHERRY, SR ;
MAZZIOTTA, JC .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1992, 16 (04) :620-633
[9]   MULTIMODALITY IMAGING OF BRAIN STRUCTURES FOR STEREOTACTIC SURGERY [J].
ZHANG, JX ;
LEVESQUE, MF ;
WILSON, CL ;
HARPER, RM ;
ENGEL, J ;
LUFKIN, R ;
BEHNKE, EJ .
RADIOLOGY, 1990, 175 (02) :435-441