BRAIN METASTASES - COMPARISON OF GADODIAMIDE INJECTION-ENHANCED MR-IMAGING AT STANDARD AND HIGH-DOSE, CONTRAST-ENHANCED CT AND NON-CONTRAST-ENHANCED MR-IMAGING

被引:63
作者
AKESON, P
LARSSON, EM
KRISTOFFERSEN, DT
JONSSON, E
HOLTAS, S
机构
[1] NYCOMED AB,STOCKHOLM,SWEDEN
[2] NYCOMED IMAGING AS,OSLO,NORWAY
关键词
BRAIN NEOPLASMS; SECONDARY; CONTRAST MEDIA; ENHANCEMENT; GADOLINIUM;
D O I
10.3109/02841859509177639
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The aim was to compare the abilities of contrast-enhanced CT, non-contrast-enhanced MR imaging and contrast-enhanced MR imaging using standard (0.1 mmol/kg b.w.) and high (0.3 mmol/kg b.w.) doses of Gadodiamide injection to detect brain metastases (i.e. blood-brain barrier damage). Sixteen patients with at least 2 metastases found by CT were evaluated by MR imaging using non-contrast-enhanced spin-echo, T1-weighted, T2-weighted sequences, and contrast-enhanced spin-echo T1-weighted sequences at 2 dose levels. Gadodiamide injection was first given at the dose of 0.1 mmol/kg b.w. After imaging, another 0.2 mmol/kg b.w. was given, yielding a cumulative dose of 0.3 mmol/kg b.w. No contrast media-related adverse events were recorded. The images were evaluated openly by one and blindly by 2 investigators and the number of metastases, size, delineation (open study) and diagnostic certainty (blind study) of each individual metastasis noted. High-dose MR imaging showed significantly more and smaller metastases than any other examination, and gave a higher diagnostic certainty. All high-dose images were superior to those with the standard dose MR imaging when compared blindly in pairs. We conclude that spin-echo MR imaging with a high dose of Gadodiamide injection is an efficient way to improve the detection of brain metastases, in particular of small ones.
引用
收藏
页码:300 / 306
页数:7
相关论文
共 27 条
[1]   CONSIDERATIONS IN THE CHOICE OF CONTRAST-MEDIA FOR MR IMAGING [J].
BRASCH, RC ;
BENNETT, HF .
RADIOLOGY, 1988, 166 (03) :897-899
[2]   THE RELATIONSHIP BETWEEN THERMODYNAMICS AND THE TOXICITY OF GADOLINIUM COMPLEXES [J].
CACHERIS, WP ;
QUAY, SC ;
ROCKLAGE, SM .
MAGNETIC RESONANCE IMAGING, 1990, 8 (04) :467-481
[3]  
DAVIS PC, 1991, AM J NEURORADIOL, V12, P293
[4]  
DAVIS PC, 1991, AJR, V12, P156
[5]   SURGICAL-TREATMENT OF SINGLE BRAIN METASTASIS - EVALUATION OF RESULTS BY COMPUTERIZED-TOMOGRAPHY SCANNING [J].
GALICICH, JH ;
SUNDARESAN, N ;
THALER, HT .
JOURNAL OF NEUROSURGERY, 1980, 53 (01) :63-67
[6]  
GALICICH JH, 1985, NEUROSURGERY, P604
[7]   GADODIAMIDE INJECTION - NONIONIC GADOLINIUM CHELATE FOR MR IMAGING OF THE BRAIN AND SPINE PHASE II-III CLINICAL-TRIAL [J].
GRECO, A ;
MCNAMARA, MT ;
LANTHIEZ, P ;
QUAY, SC ;
MICHELOZZI, G .
RADIOLOGY, 1990, 176 (02) :451-456
[8]  
HAUGEN I, 1991, JMRI-J MAGN RESON IM, V1, P186
[9]   A BLINDED CLINICAL COMPARISON OF MR IMAGING AND CT IN NEURORADIOLOGY [J].
HAUGHTON, VM ;
RIMM, AA ;
SOBOCINSKI, KA ;
PAPKE, RA ;
DANIELS, DL ;
WILLIAMS, AL ;
LYNCH, R ;
LEVINE, R .
RADIOLOGY, 1986, 160 (03) :751-755
[10]  
HAUSTEIN J, 1992, AM J NEURORADIOL, V13, P1199