FINE-NEEDLE BIOPSY OF THYROID-GLAND

被引:7
作者
BODO, M [1 ]
DOBROSSY, L [1 ]
SINKOVICS, I [1 ]
TARJAN, G [1 ]
DAUBNER, K [1 ]
机构
[1] NATL ONCOL INST,BUDAPEST,HUNGARY
关键词
aspiration cytology; diagnostic accuracy; fine‐needle biopsy; thyroid gland;
D O I
10.1002/jso.2930120402
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Critical analysis is provided by the authors on cytologic examination combined with histology of 131 patients with thyroid alterations. Cytologic examination yielded seven false‐negative and four false‐positive findings. Sensitivity of the procedure was 0.78 and the specificity 0.97. Aspiration cytology of the thyroid gland combined with other methods of examination can be considered an advance in the diagnostics of thyroid diseases. Copyright © 1979 Wiley‐Liss, Inc., A Wiley Company
引用
收藏
页码:289 / 297
页数:9
相关论文
共 11 条
[1]  
Anderson W.A., 1971, PATHOLOGY
[2]  
Bodo M, 1977, Orv Hetil, V118, P983
[3]  
BODO M, 1976, FUL ORR GEGEGYOGY, V22, P110
[4]  
CRILE G, 1973, SURG GYNECOL OBSTET, V136, P241
[5]  
EINORN J, 1962, ACTA RADIOL, V58, P321
[6]  
KOSS JG, 1972, DIAGNOSTIC CYTOLOGY
[7]  
MEISSNER WA, 1969, ATLAS TUMOUR PATHOLO
[8]  
SOOST HJ, 1976, LEHRBUCH KLINISCHEN
[9]  
TAKASHI M, 1971, COLOR ATLAS CANCER C
[10]  
Zajicek J, 1974, ASPIRATION BIOPSY 1