LATE ADVERSE REACTIONS TO NONIONIC CONTRAST-MEDIA

被引:70
作者
YOSHIKAWA, H [1 ]
机构
[1] OBIHIRO KOUSEI HOSP,DEPT RADIOL,OBIHIRO,JAPAN
关键词
COMPUTED TOMOGRAPHY (CT); CONTRAST MEDIA; COMPLICATIONS; RADIOLOGY AND RADIOLOGISTS; IATROGENIC INJURY;
D O I
10.1148/radiology.183.3.1584929
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
A prospective study of late adverse reactions to nonionic contrast media was conducted in 2,382 patients who underwent computed tomography (CT). Late reactions were defined as those that occurred more than 30 minutes but within 2 days after completion of CT. The overall rate of late reactions was 8.0% (165 of 2,052 patients), which was greater than the rate of immediate reactions (3.8% [90 of 2,382 patients]). Headache and rash were the most frequent manifestations. Three patients experienced severe vomiting, heavy drowsiness, or oliguria and required medical attention. Late reactions occurred more frequently in female patients, younger adults, and patients with histories of allergic reactions. This investigation shows that although late adverse reactions to nonionic contrast agents are not life threatening, these reactions are not uncommon. It is important that radiologists recognize these late reactions. Patients and referring physicians should be informed that late reactions can occur and may require medical attention.
引用
收藏
页码:737 / 740
页数:4
相关论文
共 15 条
[1]  
ASANO S, 1990, JPN J CLIN RADIOL, V35, P533
[2]   TRANSIENT GLOBAL AMNESIA ASSOCIATED WITH CEREBRAL-ANGIOGRAPHY PERFORMED WITH USE OF IOPAMIDOL [J].
GIANG, DW ;
KIDO, DK .
RADIOLOGY, 1989, 172 (01) :195-196
[3]  
HIGASHI S, 1988, Nippon Acta Radiologica, V48, P1364
[4]   ADVERSE REACTIONS TO IONIC AND NONIONIC CONTRAST-MEDIA - A REPORT FROM THE JAPANESE-COMMITTEE-ON-THE-SAFETY-OF-CONTRAST MEDIA [J].
KATAYAMA, H ;
YAMAGUCHI, K ;
KOZUKA, T ;
TAKASHIMA, T ;
SEEZ, P ;
MATSUURA, K .
RADIOLOGY, 1990, 175 (03) :621-628
[5]   BILATERAL PAROTID ENLARGEMENT (IODIDE MUMPS) FOLLOWING EXCRETORY UROGRAPHY [J].
KOHRI, K ;
MIYOSHI, S ;
NAGAHARA, A ;
OHTANI, M .
RADIOLOGY, 1977, 122 (03) :654-654
[6]   A LARGE TRIAL OF INTRAVENOUS CONRAY 325 AND NIOPAM 300 TO ASSESS IMMEDIATE AND DELAYED-REACTIONS [J].
MCCULLOUGH, M ;
DAVIES, P ;
RICHARDSON, R .
BRITISH JOURNAL OF RADIOLOGY, 1989, 62 (735) :260-265
[7]  
MIYAMOTO Y, 1990, Nippon Acta Radiologica, V50, P295
[8]  
NAMBU T, 1990, Nippon Acta Radiologica, V50, P1019
[9]  
SOGN EE, 1987, ACTA RADIOL, V28, P93
[10]   ACUTE RENAL-FAILURE CAUSED BY LOW-OSMOLAR RADIOGRAPHIC CONTRAST-MEDIA IN PATIENTS WITH DIABETIC NEPHROPATHY [J].
SPANGBERGVIKLUND, B ;
NIKONOFF, T ;
LUNDBERG, M ;
LARSSON, R ;
SKAU, T ;
NYBERG, P .
SCANDINAVIAN JOURNAL OF UROLOGY AND NEPHROLOGY, 1989, 23 (04) :315-317