COMPARISON OF ADAPTIVE FILTERING IN TIME-DOMAIN, TRANSFORM-DOMAIN AND FREQUENCY-DOMAIN - AN ELECTROGASTROGRAPHIC STUDY

被引:11
作者
CHEN, JD
LIN, ZY
机构
[1] Health Science Center, University of Virginia, Charlottesville, 22908, VA
关键词
ADAPTIVE FILTER; SIGNAL PROCESSING; NOISE CANCELLATION; ELECTROGASTROGRAM; MOTION ARTIFACTS;
D O I
10.1007/BF02368249
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Adaptive cancellation of motion artifacts in the electrogastrogram (EGG) is presented in this paper. The EGG is a surface measurement of gastric electrical activity. Like other noninvasive electrophysiological measurements, the EGG contains motion artifacts. A number of papers have been published on the adaptive cancellation of motion artifacts or interferences in biomedical signals. Adaptive filtering was performed in time domain in almost all of the previous publications. In this paper, however, three different sorts of adaptive filters were investigated and their efficiencies in cancellation of motion artifacts were compared with each other. These include time-domain, transform-domain, and frequency-domain adaptive filters. A series of simulations were conducted to investigate the performance of these adaptive filters in cancellation of respiratory and motion artifacts. The results show that the frequency-domain adaptive filter has superior performance over the time- and transform-domain adaptive filters in the cancellation of stationary respiratory artifacts in the EGG. Although results focus on the EGG, this paper provides useful information for adaptive filtering of other biomedical signals.
引用
收藏
页码:423 / 431
页数:9
相关论文
共 16 条
[1]   ADAPTIVE CANCELLATION TECHNIQUE IN PROCESSING MYOELECTRIC ACTIVITY OF RESPIRATORY MUSCLES [J].
AKKIRAJU, P ;
REDDY, DC .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1992, 39 (06) :652-655
[2]   ELECTROGASTROGRAPHY - MEASUREMENT, ANALYSIS AND PROSPECTIVE APPLICATIONS [J].
CHEN, J ;
MCCALLUM, RW .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1991, 29 (04) :339-350
[3]   ADAPTIVE SPECTRAL-ANALYSIS OF CUTANEOUS ELECTROGASTRIC SIGNALS USING AUTOREGRESSIVE MOVING AVERAGE MODELING [J].
CHEN, J ;
VANDEWALLE, J ;
SANSEN, W ;
VANTRAPPEN, G ;
JANSSENS, J .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1990, 28 (06) :531-536
[4]  
CHEN J, 1991, IEEE T BIOMED ENG, V37, P285
[5]   SPECTRAL-ANALYSIS OF EPISODIC RHYTHMIC VARIATIONS IN THE CUTANEOUS ELECTROGASTROGRAM [J].
CHEN, JD ;
STEWART, WR ;
MCCALLUM, RW .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1993, 40 (02) :128-135
[6]   ADAPTIVE METHOD FOR CANCELLATION OF RESPIRATORY ARTIFACT IN ELECTROGASTRIC MEASUREMENTS [J].
CHEN, JD ;
VANDEWALLE, J ;
SANSEN, W ;
VANTRAPPEN, G ;
JANSSENS, J .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1989, 27 (01) :57-63
[7]   FETAL ELECTROCARDIOGRAM ENHANCEMENT BY TIME-SEQUENCED ADAPTIVE FILTERING [J].
FERRARA, ER ;
WIDROW, B .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1982, 29 (06) :458-460
[8]  
LEE JC, 1986, IEEE T ACOUST SPEECH, V34, P499, DOI 10.1109/TASSP.1986.1164850
[9]  
LIN ZY, IN PRESS MED BIOL EN
[10]   TRANSFORM DOMAIN LMS ALGORITHM [J].
NARAYAN, SS ;
PETERSON, AM ;
NARASIMHA, MJ .
IEEE TRANSACTIONS ON ACOUSTICS SPEECH AND SIGNAL PROCESSING, 1983, 31 (03) :609-615