INSITU ASSESSMENT OF THE RAT-HEART DURING CHRONIC CARBON-MONOXIDE EXPOSURE USING NUCLEAR-MAGNETIC-RESONANCE IMAGING

被引:4
作者
BAMBACH, GA
PENNEY, DG
NEGENDANK, WG
机构
[1] WAYNE STATE UNIV, SCH MED, DEPT PHYSIOL, DETROIT, MI 48201 USA
[2] ST JOHNS HOSP, DEPT MED, DETROIT, MI USA
[3] HARPER GRACE HOSP, VAITKEVICIUS MR CTR, DETROIT, MI 48201 USA
关键词
CARBON MONOXIDE; HEART; HEMATOCRIT; LEFT VENTRICLE; NUCLEAR MAGNETIC RESONANCE IMAGING; RAT; CARDIAC HYPERTROPHY;
D O I
10.1002/jat.2550110109
中图分类号
R99 [毒物学(毒理学)];
学科分类号
100405 ;
摘要
Ventricular hypertrophy induced in male Sprague-Dawley rats by inhalation of 500 ppm carbon monoxide (40% carboxyhemoglobin level) for 0-62 days was assessed by contiguous 2-mm thick axial cardiac cross-sections, using 32 accumulated averages of ungated fast-scan gradient-recalled nuclear magnetic resonance (NMR) images. Following final imaging, the rats were sacrificed and the hematocrit and heart mass were determined. The mean outside diameter of the left ventricle plus interventricular septum (LV + S) showed a strong correlation (r = 0.73, P < 0.01) with the duration of CO exposure, while the correlation coefficients for the LV + S lumen diameter and wall thickness were marginally significant. The mean pleural space diameter also increased significantly (r = 0.64, P < 0.05) with duration of CO exposure. The ratio of the LV + S wall thickness and the lumen radius was 0.53 in the rats exposed to CO for 0-8 days; this value did not change with longer CO exposure. The LV + S outside and lumen diameter showed significant correlations to the hematocrit (r = 0.72, P < 0.05 and r = 0.66, P < 0.05, respectively), and the LV + S outside diameter correlated with the increase in the LV + S mass (r = 0.72, P < 0.05). The results achieved with NMR imaging are consistent with past morphometric studies of CO-induced ventricular hypertrophy, where heart dimensions were determined in relaxed frozen tissue, and corroborate the eccentric nature of CO-induced ventricular hypertrophy.
引用
收藏
页码:43 / 49
页数:7
相关论文
共 18 条
[1]   EFFICIENT DECOUPLER COIL DESIGN WHICH REDUCES HEATING IN CONDUCTIVE SAMPLES IN SUPERCONDUCTING SPECTROMETERS [J].
ALDERMAN, DW ;
GRANT, DM .
JOURNAL OF MAGNETIC RESONANCE, 1979, 36 (03) :447-451
[2]   TIME COURSE OF BLOOD-VOLUME CHANGE WITH CARBON-MONOXIDE INHALATION AND ITS CONTRIBUTION TO THE OVERALL CARDIOVASCULAR-RESPONSE [J].
DAVIDSON, SB ;
PENNEY, DG .
ARCHIVES OF TOXICOLOGY, 1988, 61 (04) :306-313
[3]   WALL STRESS AND PATTERNS OF HYPERTROPHY IN HUMAN LEFT-VENTRICLE [J].
GROSSMAN, W ;
JONES, D ;
MCLAURIN, LP .
JOURNAL OF CLINICAL INVESTIGATION, 1975, 56 (01) :56-64
[4]   FLASH IMAGING - RAPID NMR IMAGING USING LOW FLIP-ANGLE PULSES [J].
HAASE, A ;
FRAHM, J ;
MATTHAEI, D ;
HANICKE, W ;
MERBOLDT, KD .
JOURNAL OF MAGNETIC RESONANCE, 1986, 67 (02) :258-266
[5]   HEMODYNAMIC-RESPONSES TO ACUTE CARBOXYHEMOGLOBINEMIA IN THE RAT [J].
KANTEN, WE ;
PENNEY, DG ;
FRANCISCO, K ;
THILL, JE .
AMERICAN JOURNAL OF PHYSIOLOGY, 1983, 244 (03) :H320-H327
[6]  
MATTHAEI D, 1986, Magnetic Resonance Imaging, V4, P381, DOI 10.1016/0730-725X(86)90043-3
[7]  
PENNEY D, 1974, GROWTH, V38, P321
[8]   A REVIEW - HEMODYNAMIC-RESPONSE TO CARBON-MONOXIDE [J].
PENNEY, DG .
ENVIRONMENTAL HEALTH PERSPECTIVES, 1988, 77 :121-130
[9]   CARDIAC COMPLIANCE AND DIMENSIONS IN CARBON MONOXIDE-INDUCED CARDIOMEGALY [J].
PENNEY, DG ;
BARTHEL, BG ;
SKONEY, JA .
CARDIOVASCULAR RESEARCH, 1984, 18 (05) :270-276
[10]   HEART AND LUNG HYPERTROPHY, CHANGES IN BLOOD-VOLUME, HEMATOCRIT AND PLASMA-RENIN ACTIVITY IN RATS CHRONICALLY EXPOSED TO INCREASING CARBON-MONOXIDE CONCENTRATIONS [J].
PENNEY, DG ;
DAVIDSON, SB ;
GARGULINSKI, RB ;
CALDWELLAYRE, TM .
JOURNAL OF APPLIED TOXICOLOGY, 1988, 8 (03) :171-178