FACTORS PREDICTING POSTOPERATIVE SENTENCE SCORES IN POSTLINGUISTICALLY DEAF ADULT COCHLEAR IMPLANT PATIENTS

被引:146
作者
BLAMEY, PJ
PYMAN, BC
CLARK, GM
DOWELL, RC
GORDON, M
BROWN, AM
HOLLOW, RD
机构
[1] Department of Otolaryngology, University of Melbourne, East Melbourne
关键词
COCHLEAR IMPLANTATION; PROFOUND DEAFNESS; PROMONTORY STIMULATION; SENTENCE TEST;
D O I
10.1177/000348949210100410
中图分类号
R76 [耳鼻咽喉科学];
学科分类号
100213 [耳鼻咽喉科学];
摘要
A sample of 64 postlinguistically profoundly to totally deaf adult cochlear implant patients were tested without lipreading by means of the Central Institute for the Deaf (CID) sentence test 3 months postoperatively. Preoperative promontory stimulation results (thresholds, gap detection, and frequency discrimination), age, duration of profound deafness, cause of deafness, lipreading ability, postoperative intracochlear thresholds and dynamic ranges for electrical stimulation, depth of insertion of the electrode array into the scala tympani, and number of electrodes in use were considered as possible factors that might be related to the postoperative sentence scores. A multiple regression analysis with stepwise inclusion of independent variables indicated that good gap detection and frequency discrimination during preoperative promontory testing, larger numbers of electrodes in use, and greater dynamic ranges for intracochlear electrical stimulation were associated with better CID scores. The CID scores tended to decrease with longer periods of profound deafness.
引用
收藏
页码:342 / 348
页数:7
相关论文
共 24 条
[1]
VOWEL AND CONSONANT RECOGNITION OF COCHLEAR IMPLANT PATIENTS USING FORMANT-ESTIMATING SPEECH PROCESSORS [J].
BLAMEY, PJ ;
DOWELL, RC ;
BROWN, AM ;
CLARK, GM ;
SELIGMAN, PM .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1987, 82 (01) :48-57
[2]
ACOUSTIC PARAMETERS MEASURED BY A FORMANT-ESTIMATING SPEECH PROCESSOR FOR A MULTIPLE-CHANNEL COCHLEAR IMPLANT [J].
BLAMEY, PJ ;
DOWELL, RC ;
CLARK, GM ;
SELIGMAN, PM .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1987, 82 (01) :38-47
[3]
BRACKMANN DE, 1978, OTOLARYNG CLIN N AM, V11, P195
[4]
TELEPHONE USE BY A MULTI-CHANNEL COCHLEAR IMPLANT PATIENT - AN EVALUATION USING OPEN-SET CID SENTENCES [J].
BROWN, AM ;
CLARK, GM ;
DOWELL, RC ;
MARTIN, LFA ;
SELIGMAN, PM .
JOURNAL OF LARYNGOLOGY AND OTOLOGY, 1985, 99 (03) :231-238
[5]
A MULTI-CHANNEL HEARING PROSTHESIS FOR PROFOUND-TO-TOTAL HEARING-LOSS [J].
CLARK, GM ;
TONG, YC ;
PATRICK, JF ;
SELIGMAN, PM ;
CROSBY, PA ;
KUZMA, JA ;
MONEY, DK .
JOURNAL OF MEDICAL ENGINEERING & TECHNOLOGY, 1984, 8 (01) :3-8
[6]
SURGERY FOR AN IMPROVED MULTIPLE-CHANNEL COCHLEAR IMPLANT [J].
CLARK, GM ;
PYMAN, BC ;
BAILEY, QE ;
WEBB, RL ;
SHEPHERD, RK .
ANNALS OF OTOLOGY RHINOLOGY AND LARYNGOLOGY, 1984, 93 (03) :204-207
[7]
WORD RECOGNITION BY 50 PATIENTS FITTED WITH THE SYMBION MULTICHANNEL COCHLEAR IMPLANT [J].
DORMAN, MF ;
HANNLEY, MT ;
DANKOWSKI, K ;
SMITH, L ;
MCCANDLESS, G .
EAR AND HEARING, 1989, 10 (01) :44-49
[8]
DOWELL RC, 1985, ANN OTO RHINOL LARYN, V94, P244
[9]
SPEECH-PERCEPTION USING A 2-FORMANT 22-ELECTRODE COCHLEAR PROSTHESIS IN QUIET AND IN NOISE [J].
DOWELL, RC ;
SELIGMAN, PM ;
BLAMEY, PJ ;
CLARK, GM .
ACTA OTO-LARYNGOLOGICA, 1987, 104 (5-6) :439-446
[10]
DOWELL RC, 1986, ARCH OTOLARYNGOL, V112, P1054