DUAL CONTRAST ENHANCEMENT OF BOTH T1-WEIGHTED AND T2-WEIGHTED SEQUENCES USING ULTRASMALL SUPERPARAMAGNETIC IRON-OXIDE

被引:33
作者
SMALL, WC
NELSON, RC
BERNARDINO, ME
机构
[1] Emory University School of Medicine, Department of Radiology, Atlanta
关键词
CONTRAST MEDIA; EXPERIMENTAL STUDIES; MAGNETIC RESONANCE; CONTRAST ENHANCEMENT; IRON; LIVER; MR STUDIES; SPLEEN;
D O I
10.1016/0730-725X(93)90006-Y
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
BMS 180549 (previously AMI-227), an ultrasmall superparamagnetic iron particulate agent, was investigated to determine its utility as a contrast agent on T1-weighted, as well as T2-weighted sequences, as a function of route of administration, (intravenous versus selective arterial) and concentration. Twelve farm pigs were divided into three groups of four each by route of administration (intravenous, selective superior mesenteric, or selective hepatic arterial injection). 10 mumol/kg and 20 mumol/kg dosages were given and evaluated both immediately after and 20-24 hr after contrast infusion, using both spin-echo and gradient-echo T1 and T2-weighted sequences. Significant postcontrast liver and spleen enhancement was noted at both concentrations, regardless of route of administration on both T1- and T2-weighted sequences. The earliest postcontrast T1-weighted sequence obtained during the 1-3 min interval following IV administration of high dose (20 mumol/kg) contrast demonstrated an average of +42.8% liver and +249.0% spleen enhancement; 24 hr later this decreased to 0 and 7.2%, respectively. The earliest postcontrast T2-weighted sequence obtained during the 8-17 min interval post high-dose IV contrast showed an average of -75.8% decrease in liver and -28.7% decrease in spleen signal intensity; 24 hr later the magnitude of these changes diminished to -33.1% and +2.5%, respectively. No significant difference was noted in liver or spleen enhancement, regardless of route of contrast administration (intravenous versus intraarterial).
引用
收藏
页码:645 / 654
页数:10
相关论文
共 20 条
[1]  
Stark, Weissleder, Elizondo, Et al., Supraparamagnetic iron oxide: Clinical application as a contrast agent for MR imaging of the liver, Radiology, 168, pp. 297-301, (1988)
[2]  
Weissleder, Elizondo, Stark, Et al., The diagnosis of splenic lymphoma by MR imaging: Value of superparamagnetic iron oxide, AJR, 152, pp. 175-180, (1989)
[3]  
Weissleder, Elizondo, Wittenberg, Lee, Josephson, Brady, Ultrasmall superparamagnetic iron oxide: An intravenous contrast agent for assessing lymph nodes with MR imaging, Radiology, 175, pp. 494-498, (1990)
[4]  
Sene'terre, Weissleder, Jaramillo, Et al., Bone marrow: Ultrasmall superparamagnetic iron oxide for MR imaging, Radiology, 179, pp. 528-533, (1991)
[5]  
Weissleder, Elizondo, Wittenberg, Rabito, Bengele, Josephson, Ultrasmall super-paramagnetic iron oxide: Characterization of a new class of contrast agents for MR imaging, Radiology, 175, pp. 489-493, (1990)
[6]  
Shibata, Weissleder, Schaffer, Shen, Pepisov, Brady, Tissue relaxivities and detectability of monocrystalline iron oxides, Book of abstracts: Eleventh Annual Meeting of the Society of Magnetic Resonance in Medicine, (1992)
[7]  
Brasch, New directions in the development of MR imaging contrast media, Radiology, 183, pp. 1-11, (1992)
[8]  
Hamm, Wolf, Felix, Conventional and rapid MR imaging of the liver with gadolinium-DTPA, Radiology, 164, pp. 357-362, (1987)
[9]  
Pavone, Patrizio, Buoni, Et al., Comparison of Gd-BOPTA with Gd-DTPA in MR imaging of rat liver, Radiology, 176, pp. 61-64, (1990)
[10]  
Weinmann, Schuhmann-Giampieri, Schmitt-Willich, Vogler, Frenzel, Gries, A new lipophilic gadolinium chelate as a tissue-specific contrast-enhanced magnetic resonance, Book of abstracts: Tenth Annual Meeting of the Society of Magnetic Resonance in Medicine, pp. 80-87, (1991)