HIGH SPATIAL-RESOLUTION PARTICLE PHYSICS DETECTORS

被引:8
作者
EISLER, FR
机构
[1] CUNY, S.I., NY 10301, St. George Campus
来源
NUCLEAR INSTRUMENTS & METHODS | 1979年 / 163卷 / 01期
关键词
D O I
10.1016/0029-554X(79)90037-5
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The basic principles needed for the construction of high spatial resolution particle physics detectors are presented and show that resolutions approaching one micron in all three spatial dimensions can be attained. This permits the study of states with lifetimes as small as 10-16 s. The high spatial resolution technique applied to bubble chambers transforms them into new instruments capable of handling beam fluxes of 106 particles per second. This flux yields 106 events per μb per 2×105 accelerator machine cycles. As bubble chambers can be built using liquid hydrogen, small cross-section reactions producing new massive short-lived states and dense multihadron shower events can be studied in hydrogen collisions with high statistical and systematic accuracy and precision. These same principles can be applied to the construction of high spatial resolution neutrino bubble chamber detectors ideal for tau-neutrino detection. Small thin ultrasonically expanded bubble chambers of still higher spatial resolution are possible. Expansion and diffusion cloud chambers can also be built as high spatial resolution detectors of very low density and finally, track imaging counter detectors of high spatial resolution may also be possible. © 1979.
引用
收藏
页码:105 / 111
页数:7
相关论文
共 7 条
[1]  
ANSLEY DA, 1970, APPLICATIONS HOLOGRA
[2]   IMAGING THROUGH TURBULENT WATER USING SPECKLE REFERENCE HOLOGRAPHY [J].
CATHEY, WT ;
HADWIN, JF ;
PACE, JD .
APPLIED OPTICS, 1973, 12 (11) :2683-2685
[3]   COMPARISON OF EXPERIMENTAL AND THEORETICAL HOLOGRAPHIC IMAGE RADIANCE [J].
KASPAR, FG ;
LAMBERTS, RL ;
EDGETT, CD .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA, 1968, 58 (09) :1289-&
[4]   APPLICATION OF HOLOGRAM TECHNIQUES FOR PARTICLE SIZE ANALYSIS [J].
THOMPSON, BJ ;
WARD, JH ;
ZINKY, WR .
APPLIED OPTICS, 1967, 6 (03) :519-&
[5]   IN-LINE HOLOGRAM SYSTEM FOR BUBBLE-CHAMBER RECORDING [J].
WARD, JH ;
THOMPSON, BJ .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA, 1967, 57 (02) :275-&
[6]   OBTAINING INCREASED FOCAL DEPTH IN BUBBLE CHAMBER PHOTOGRAPHY BY AN APPLICATION OF HOLOGRAM PRINCIPLE [J].
WELFORD, WT .
APPLIED OPTICS, 1966, 5 (05) :872-&
[7]   HOLOGRAPHY IN A RANDOM SPATIALLY INHOMOGENEOUS MEDIUM [J].
YURA, HT .
APPLIED OPTICS, 1973, 12 (06) :1188-1192