PREOPERATIVE LOCALIZATION OF NONPALPABLE BREAST-LESIONS - TECHNIQUE AND RESULTS

被引:3
作者
SCHMITT, R
GULLOTTA, U
SPINDLERTHIELE, S
KELLER, E
BUSING, CM
机构
[1] KLINIKUMS INGOLSTADT,FRAUENKLIN,INGOLSTADT,GERMANY
[2] KLINIKUMS INGOLSTADT,INST PATHOL,INGOLSTADT,GERMANY
来源
FORTSCHRITTE AUF DEM GEBIETE DER RONTGENSTRAHLEN UND DER NEUEN BILDGEBENDEN VERFAHREN | 1992年 / 157卷 / 05期
关键词
BREAST LESION; HOOKED MANDRIN; PREOPERATIVE LOCALIZATION; WIRE GRID COMPRESSION PLATE;
D O I
10.1055/s-2008-1033051
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
189 non-palpable breast lesions in 182 patients were localized using conventional mammographic apparatus, a wire grid compression plate and a canula with a hooked mandrin. The technique of the examination for defining the lesion in three planes and fixation of the lesion with the wire is described. In 173 instances (91,5 %), the lesion was found at the first biopsy and subsequent biopsies were necessary on only 24 occasions. One lesion (0,5 %) was missed completely. 47 carcinomas were found (24,9 %) and the incidence of malignancy increased from 14,3 % to 33,3 % during the series. The mean ratio defining the size of the biopsy and the size of the lesion was 3.3 and indicates good preservation of breast tissue. Radiographs of the specimen taken with compression showed 186 lesions (98,4 %). The method, which is comfortable for the patient, provides satisfactory detection and localization of the lesions; results are similar to those of stereotactic methods but this method is quicker and much less expensive.
引用
收藏
页码:512 / 517
页数:6
相关论文
共 35 条
[1]  
ADYE B, 1988, ARCH SURG-CHICAGO, V123, P37
[2]  
BAUERMEISTER DE, 1973, AM J CLIN PATHOL, V59, P782
[3]   STEREOTAXIC INSTRUMENT FOR NEEDLE-BIOPSY OF MAMMA [J].
BOLMGREN, J ;
JACOBSON, B ;
NORDENSTROM, B .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1977, 129 (01) :121-125
[4]  
Brezina K, 1980, Rontgenpraxis, V33, P235
[5]   NEEDLE LOCALIZATION OF NONPALPABLE BREAST-LESIONS WITH A PORTABLE DUAL-GRID COMPRESSION SYSTEM - WORK IN PROGRESS [J].
CHEN, HH ;
BERNSTEIN, JR ;
PAIGE, ML ;
CRAMPTON, AR .
RADIOLOGY, 1989, 170 (03) :687-690
[6]   BREAST SPECIMEN RADIOGRAPHY - EVALUATION OF A COMPRESSION DEVICE [J].
CHILCOTE, WA ;
DAVIS, GA ;
SUCHY, P ;
PAUSHTER, DM .
RADIOLOGY, 1988, 168 (02) :425-427
[7]  
DAVIS PS, 1987, AM J ROENTGENOL, V160, P787
[8]   NONPALPABLE BREAST-TUMORS - DIAGNOSIS WITH STEREOTAXIC LOCALIZATION AND FINE-NEEDLE ASPIRATION [J].
DOWLATSHAHI, K ;
GENT, HJ ;
SCHMIDT, R ;
JOKICH, PM ;
BIBBO, M ;
SPRENGER, E .
RADIOLOGY, 1989, 170 (02) :427-433
[9]   NONPALPABLE BREAST-LESIONS - FINDINGS OF STEREOTAXIC NEEDLE-CORE BIOPSY AND FINE-NEEDLE ASPIRATION CYTOLOGY [J].
DOWLATSHAHI, K ;
YAREMKO, ML ;
KLUSKENS, LF ;
JOKICH, PM .
RADIOLOGY, 1991, 181 (03) :745-750