HIGHLY SENSITIVE AND SELECTIVE DETERMINATION OF RIBOFLAVIN BY FLOW-INJECTION ANALYSIS USING PARALLEL DUAL-CYLINDER MICROELECTRODES

被引:15
作者
PENG, WF [1 ]
LI, HM [1 ]
WANG, E [1 ]
机构
[1] CHINESE ACAD SCI, CHANGCHUN INST APPL CHEM, ELECTROANALYT CHEM LAB, CHANGCHUN 130022, PEOPLES R CHINA
基金
中国国家自然科学基金;
关键词
D O I
10.1016/0022-0728(94)03409-5
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A novel wall-jet cell with parallel dual cylinder (PDC) microelectrodes was constructed and used for flow injection analysis (FLA). The detector takes the advantages of ''redox recycling'' between bipotentiostated microcylinder electrodes (- 0.4 V/SCE and 0.0 V/SCE respectively) and shows high sensitivity and selectivity for riboflavin which is electrochemically reversible. In 0.1 mol 1(-1) NaHSO3 media and at a flow rate of 1.0 ml 1(-1), 56.8% collection efficiency was found at a PDC device with cylinder diameter of 20 mum and an interelectrode gap of 2 mum. With this device, the FIA peak current at collector electrode had a linear relationship with riboflavin concentration over a wide range (from 70 ng to 35 pg), and the detection limit was 35 pg (signal-to-noise ratio of 3). For 10 successive replicate injections of 35 ng and 3.5 ng of the analyte, relative standard deviations were 1.7% and 2.8% respectively. This method was applied to the direct determination of riboflavin (vitamin B2) in multivitamin tablets without the usual liquid chromatographic separation procedures and good results were obtained. The method proposed is simple, rapid and economic.
引用
收藏
页码:185 / 192
页数:8
相关论文
共 38 条
[1]   THIN-LAYER ELECTROCHEMISTRY - STEADY-STATE METHODS OF STUDYING RATE PROCESSES [J].
ANDERSON, LB ;
REILLEY, CN .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1965, 10 (04) :295-&
[2]   ELECTROCHEMICAL RESPONSE AT MICROARRAY ELECTRODES IN FLOWING STREAMS AND DETERMINATION OF CATECHOLAMINES [J].
AOKI, A ;
MATSUE, T ;
UCHIDA, I .
ANALYTICAL CHEMISTRY, 1990, 62 (20) :2206-2210
[3]   QUANTITATIVE-ANALYSIS OF REVERSIBLE DIFFUSION-CONTROLLED CURRENTS OF REDOX SOLUBLE SPECIES AT INTERDIGITATED ARRAY ELECTRODES UNDER STEADY-STATE CONDITIONS [J].
AOKI, K ;
MORITA, M ;
NIWA, O ;
TABEI, H .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1988, 256 (02) :269-282
[4]   CAPABILITY OF A PHOTODIODE ARRAY DETECTOR FOR VITAMIN ANALYSIS [J].
ARAI, Y ;
HANAI, T .
JOURNAL OF LIQUID CHROMATOGRAPHY, 1988, 11 (11) :2409-2418
[5]   CONSTRUCTION AND USE OF PAIRED AND TRIPLE BAND MICROELECTRODES IN SOLUTIONS OF LOW IONIC-STRENGTH [J].
BARTELT, JE ;
DEAKIN, MR ;
AMATORE, C ;
WIGHTMAN, RM .
ANALYTICAL CHEMISTRY, 1988, 60 (19) :2167-2169
[6]   AMPEROMETRIC DETECTION OF PICOMOLE SAMPLES IN A MICRODISK ELECTROCHEMICAL FLOW-JET CELL WITH DILUTE SUPPORTING ELECTROLYTE [J].
BIXLER, JW ;
BOND, AM .
ANALYTICAL CHEMISTRY, 1986, 58 (13) :2859-2863
[7]   ELECTROCHEMISTRY IN ORGANIC-SOLVENTS WITHOUT SUPPORTING ELECTROLYTE USING PLATINUM MICROELECTRODES [J].
BOND, AM ;
FLEISCHMANN, M ;
ROBINSON, J .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1984, 168 (1-2) :299-312
[8]  
BREYER B, 1960, COLLECT CZECH CHEM C, V25, P3348
[9]   LIQUID-CHROMATOGRAPHY DETECTOR BASED ON SINGLE AND TWIN ELECTRODE THIN-LAYER ELECTROCHEMISTRY - APPLICATION TO DETERMINATION OF CATECHOLAMINES IN BLOOD-PLASMA [J].
FENN, RJ ;
SIGGIA, S ;
CURRAN, DJ .
ANALYTICAL CHEMISTRY, 1978, 50 (08) :1067-1073
[10]   DESIGN AND EVALUATION OF ELECTROCHEMICAL DETECTORS FOR HPLC [J].
FLEET, B ;
LITTLE, CJ .
JOURNAL OF CHROMATOGRAPHIC SCIENCE, 1974, 12 (12) :747-752