CARDIAC EJECTION FRACTION - PHANTOM STUDY COMPARING CINE MR IMAGING, RADIONUCLIDE BLOOD POOL IMAGING, AND VENTRICULOGRAPHY

被引:59
作者
DEBATIN, JF
NADEL, SN
PAOLINI, JF
SOSTMAN, HD
COLEMAN, RE
EVANS, AJ
BEAM, C
SPRITZER, CE
BASHORE, TM
机构
[1] Department of Radiology, Duke University Medical Center, Durham, North Carolina, 27710
[2] Department of Medicine, Duke University Medical Center, Durham, North Carolina, 27710, Box 3808, Erwin Rd
来源
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING | 1992年 / 2卷 / 02期
关键词
CINE STUDIES; COMPARATIVE STUDIES; HEART; EJECTION FRACTION; FUNCTION; MR; VENTRICLES; PHANTOMS;
D O I
10.1002/jmri.1880020205
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The accuracy and reproducibility of cardiac ejection fraction (EF) measurements based on cine magnetic resonance (MR) imaging, radionuclide multigated acquisition (MUGA) blood pool imaging, and angiographic ventriculography were evaluated by comparing them with a volumetrically determined standard. A biventricular, compliant, fluid-filled heart phantom was developed to mimic normal cardiac anatomy and physiology. Ventricular EFs were measured with cine MR imaging by summation of nine contiguous 10-mm-thick sections in short and long axis, with single-plane ventriculography, and with MUGA. Three measurements were performed with each modality for each of three EFs. Ventriculography was least accurate, with average relative errors ranging from 7.9% for the largest EF to 60.1% for the smallest. Cine MR was most accurate, with average relative errors ranging from 4.4% to 8.5%. MUGA EF measurements showed good correlation, with average relative errors ranging from 7.1% to 22.4%. Comparison of the error variances for the three modalities with the F test revealed that MR and MUGA EF measurements were significantly more accurate than those based on ventriculography (P < .01). No significant difference was demonstrated between the accuracy of short- and long-axis cine MR acquisitions.
引用
收藏
页码:135 / 142
页数:8
相关论文
共 42 条
  • [1] Tscholakoff D, Higgins CB, Gated magnetic resonance imaging for assessment of cardiac function and myocardial infarction, Radiol Clin North Am, 23, pp. 449-457, (1985)
  • [2] Pohost GM, Canby RC, Nuclear magnetic resonance imaging: current applications and future prospects, Circulation, 75, pp. 88-95, (1987)
  • [3] Rossum AC, Visser FC, Sprenger M, Et al., Evaluation of magnetic resonance imaging for determination of left ventricular ejection fraction and comparison with angiography, Am JCardiol, 62, pp. 628-633, (1988)
  • [4] Utz JA, Herfkens RJ, Heinsimer JA, Et al., Cine MR determination of left ventricular ejection fraction, AJR, 148, pp. 839-843, (1987)
  • [5] Haase A, Matthei D, Hanicke W, Rapid NMR imaging using low flip‐angle pulses, J Magn Reson, 67, pp. 258-266, (1986)
  • [6] Pflugfelder PW, Sechtem UPU, White RD, Et al., Quantification of regional myocardial function by rapid cine MR imaging, AJR, 150, pp. 523-529, (1988)
  • [7] Longmore DB, Underwood SR, Hounsfleld GN, Et al., Dimensional accuracy of magnetic resonance in studies of the heart, Lancet, 1, pp. 1360-1362, (1985)
  • [8] Markiewicz W, Sechtem U, Kirby R, Et al., Measurement of ventricular volumes in the dog by nuclear magnetic resonance imaging, J Am Coll Cardiol, 10, pp. 170-177, (1987)
  • [9] van Rossum AC, Visser FC, van Eenige MJ, Et al., Magnetic resonance imaging of the heart for determination of ejection fraction, Int J Cardiol, 18, pp. 53-63, (1988)
  • [10] Le Page R, Crandall CR, Hood CH, Et al., A brief evaluation of cardiac gated MRI in left ventricular ejection fraction determinations: a comparison with standard left ventriculography DSA and nuclear medicine, Ann Radiol, 29, pp. 87-90, (1986)