WEAK ELECTRIC-CURRENT ACCELERATES MOTONEURON REGENERATION IN THE SCIATIC-NERVE OF 10-MONTH-OLD RATS

被引:32
作者
POMERANZ, B [1 ]
CAMPBELL, JJ [1 ]
机构
[1] UNIV TORONTO,DEPT PHYSIOL,TORONTO M5S 1A1,ONTARIO,CANADA
基金
加拿大自然科学与工程研究理事会;
关键词
REGENERATION; NERVE REGENERATION; NERVE INJURY; SCIATIC; MOTONEURON; ELECTROTHERAPY; DIRECT CURRENT; ELECTRIC FIELD;
D O I
10.1016/0006-8993(93)91247-P
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
When a weak direct current (DC) of 10 muA driven by an implantable device was applied to a crushed sciatic nerve in 9-10-month-old rats, regeneration was accelerated as assessed electrophysiologically. Rats underwent a sciatic nerve crush of the right leg and were randomly assigned to one of three groups: (i) Cathode Distal (CD); (ii) Sham Implant (SI); or (iii) No Implant (NI). On post-operative days 25-39 each Tat received a measurement of evoked electromyograms (EMG) in the foot. In addition each rat received a behavioural test score (BTS). This BTS correlated well with the evoked EMG results showing the behavioural relevance of the EMG results. NI rats performed the same as SI in the evoked EMG procedure, but CD rats performed significantly better than both the control groups. The recovery period in the CD rats was 21% shorter than in either the sham-treated or untreated controls showing that weak DC can greatly enhance nerve regeneration in adult rats. This result was in contrast to previous work in younger rats where DC treatments had no effects. The discrepancy is discussed in relation to the slowing of regeneration in older rats.
引用
收藏
页码:271 / 278
页数:8
相关论文
共 41 条
[1]   PIEZOELECTRIC QUIDANCE CHANNELS ENHANCE REGENERATION IN THE MOUSE SCIATIC-NERVE AFTER AXOTOMY [J].
AEBISCHER, P ;
VALENTINI, RF ;
DARIO, P ;
DOMENICI, C ;
GALLETTI, PM .
BRAIN RESEARCH, 1987, 436 (01) :165-168
[2]   RECOVERY OF PERIPHERAL-NERVE FUNCTION AFTER AXOTOMY - EFFECT OF TRIIODOTHYRONINE [J].
BERENBERG, RA ;
FORMAN, DS ;
WOOD, DK ;
DESILVA, A ;
DEMAREE, J .
EXPERIMENTAL NEUROLOGY, 1977, 57 (02) :349-363
[3]   USE OF EXOGENOUS ELECTRIC-CURRENT IN THE TREATMENT OF DELAYED LESIONS IN PERIPHERAL-NERVES [J].
BEVERIDGE, JA ;
POLITIS, MJ .
PLASTIC AND RECONSTRUCTIVE SURGERY, 1988, 82 (04) :573-577
[4]  
Borgens R B, 1988, Adv Neurol, V47, P547
[5]   ENHANCED SPINAL-CORD REGENERATION IN LAMPREY BY APPLIED ELECTRIC-FIELDS [J].
BORGENS, RB ;
ROEDERER, E ;
COHEN, MJ .
SCIENCE, 1981, 213 (4508) :611-617
[6]   BIOELECTRICITY AND REGENERATION .1. INITIATION OF FROG LIMB REGENERATION BY MINUTE CURRENTS [J].
BORGENS, RB ;
VANABLE, JW ;
JAFFE, LF .
JOURNAL OF EXPERIMENTAL ZOOLOGY, 1977, 200 (03) :403-416
[7]   SMALL ARTIFICIAL CURRENTS ENHANCE XENOPUS LIMB REGENERATION [J].
BORGENS, RB ;
VANABLE, JW ;
JAFFE, LF .
JOURNAL OF EXPERIMENTAL ZOOLOGY, 1979, 207 (02) :217-225
[8]   TRANSECTED DORSAL COLUMN AXONS WITHIN THE GUINEA-PIG SPINAL-CORD REGENERATE IN THE PRESENCE OF AN APPLIED ELECTRIC-FIELD [J].
BORGENS, RB ;
BLIGHT, AR ;
MURPHY, DJ ;
STEWART, L .
JOURNAL OF COMPARATIVE NEUROLOGY, 1986, 250 (02) :168-180
[9]   BEHAVIORAL RECOVERY INDUCED BY APPLIED ELECTRIC-FIELDS AFTER SPINAL-CORD HEMISECTION IN GUINEA-PIG [J].
BORGENS, RB ;
BLIGHT, AR ;
MCGINNIS, ME .
SCIENCE, 1987, 238 (4825) :366-369
[10]   A NEW METHOD TO STUDY MOTONEURON REGENERATION USING ELECTROMYOGRAMS SHOWS THAT REGENERATION SLOWS WITH AGE IN RAT SCIATIC-NERVE [J].
CAMPBELL, JJ ;
POMERANZ, B .
BRAIN RESEARCH, 1993, 603 (02) :264-270