ISOFLURANE COMPARED WITH NITROUS-OXIDE ANESTHESIA FOR INTRAOPERATIVE MONITORING OF SOMATOSENSORY-EVOKED POTENTIALS

被引:30
作者
LAM, AM
SHARAR, SR
MAYBERG, TS
ENG, CC
机构
[1] Department of Anesthesiology, Harborview Medical Center, University of Washington, Seattle, 98104, WA
[2] Phoenix Anesthesia Group, Phoenix, 85014, AZ
来源
CANADIAN JOURNAL OF ANAESTHESIA-JOURNAL CANADIEN D ANESTHESIE | 1994年 / 41卷 / 04期
关键词
ANESTHETICS; INHALED; ISOFLURANE; NITROUS OXIDE; MONITORING; EVOKED POTENTIALS; SOMATOSENSORY-EVOKED POTENTIAL;
D O I
10.1007/BF03009907
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Intraoperative monitoring of somatosensory-evoked potentials is a routine procedure. To determine the depressant effect of nitrous oxide relative to isoflurane, the authors recorded the scalp, cervical and brachial plexus-evoked responses to stimulation of the median nerve under different anaesthetic conditions. Eight subjects, age 35 +/- 6 (SD) yr, weight 68 +/- 12 kg, were studied. Following recording of awake control responses, anaesthesia was induced with thiopentone 5 mg . kg-1 and fentanyl 3 mug . kg-1 and was followed by succinylcholine 1 mg . kg-1. During normocapnia and normothermia, and with a maintenance infusion of fentanyl 3 mug . kg-1. hr-1, evoked potential recording was repeated under three different anaesthetic conditions; 0.6 MAC nitrous oxide, 0.6 MAC nitrous oxide +/- 0.6 MAC isoflurane, and 0.6 MAC isoflurane. Among the anaesthetic conditions, the combination of nitrous oxide-isoflurane had the most depressant effect on the cortical amplitude (67 +/- 4% reduction, P < 0.05). Nitrous oxide decreased the cortical amplitude more than an equipotent dose of isoflurane (60 +/- 4% vs 48 +/- 7%, P < 0.05). The latency was unchanged by nitrous oxide, but increased slightly by isoflurane and isoflurane-nitrous oxide anaesthesia (1.0 and 0.9 msec respectively, P < 0.05). We conclude that somatosensory-evoked potential monitoring is feasible both during nitrous oxide anaesthesia and isoflurane anaesthesia, but the cortical amplitude is better preserved during 0.6 MAC of isoflurane alone relative to 0.6 MAC of nitrous oxide alone. The depressant effect is maximal during nitrous oxide-isoflurane anaesthesia but less than the predicted additive effect.
引用
收藏
页码:295 / 300
页数:6
相关论文
共 20 条
  • [1] GRUNDY BL, 1984, MT SINAI J MED, V51, P585
  • [2] HORNBEIN TF, 1982, ANESTH ANALG, V61, P553
  • [3] CONDUCTION TIME IN CENTRAL SOMATOSENSORY PATHWAYS IN MAN
    HUME, AL
    CANT, BR
    [J]. ELECTROENCEPHALOGRAPHY AND CLINICAL NEUROPHYSIOLOGY, 1978, 45 (03): : 361 - 375
  • [4] ADJUSTING FOR BASELINE - CHANGE OR PERCENTAGE CHANGE
    KAISER, L
    [J]. STATISTICS IN MEDICINE, 1989, 8 (10) : 1183 - 1190
  • [5] MONITORING ELECTROPHYSIOLOGIC FUNCTION DURING CAROTID ENDARTERECTOMY - A COMPARISON OF SOMATOSENSORY EVOKED-POTENTIALS AND CONVENTIONAL ELECTROENCEPHALOGRAM
    LAM, AM
    MANNINEN, PH
    FERGUSON, GG
    NANTAU, W
    [J]. ANESTHESIOLOGY, 1991, 75 (01) : 15 - 21
  • [6] LAM AM, 1992, ANESTHESIOL CLIN N A, V10, P657
  • [7] EFFECTS OF ENFLURANE, ISOFLURANE, AND NITROUS-OXIDE ON SOMATOSENSORY EVOKED-POTENTIALS DURING FENTANYL ANESTHESIA
    MCPHERSON, RW
    MAHLA, M
    JOHNSON, R
    TRAYSTMAN, RJ
    [J]. ANESTHESIOLOGY, 1985, 62 (05) : 626 - 633
  • [8] Nuwer M., 1986, EVOKED POTENTIAL MON, P49
  • [9] PATHAK KS, 1984, ANESTH ANALG, V63, P833
  • [10] EFFECTS OF HALOTHANE, ENFLURANE, AND ISOFLURANE ON SOMATOSENSORY EVOKED-POTENTIALS DURING NITROUS-OXIDE ANESTHESIA
    PATHAK, KS
    AMMADIO, M
    KALAMCHI, A
    SCOLES, PV
    SHAFFER, JW
    MACKAY, W
    [J]. ANESTHESIOLOGY, 1987, 66 (06) : 753 - 757