PRELIMINARY EXPERIENCE WITH PORTABLE DIGITAL IMAGING FOR INTENSIVE-CARE RADIOGRAPHY

被引:14
作者
MARGLIN, SI
ROWBERG, AH
GODWIN, JD
机构
[1] Department of Radiology, University of Washington, Seattle, WA
关键词
D O I
10.1097/00005382-199001000-00008
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
A digital radiography system based on reusable, photostimulable phosphor technology was evaluated in approximately 3500 portable chest radiographs of patients in an intensive care unit. The system functioned well in this application. No major problems were encountered in the visualization of tubes or catheters or in the detection of pneumotboraces. Assessment of fluid volume status or the presence of small pleural effusions, especially when these were bilateral, was initially somewhat difficult but became easier as investigators became familiar with the system. Radiologists were quicker than nonradiologists to accept the minimized two-on-one display format. Critical evaluation of the overall performance of digital systems such as this one is needed for a better definition of the system's strengths and weaknesses. Specifically, statistical analyses of the ability to detect disease states such as pneumothoraces, interstitial lung disease, lung nodules, and pleural abnormalities need to be performed. © 1990 Aspen Publishers, Inc.
引用
收藏
页码:49 / 54
页数:6
相关论文
共 12 条
[1]  
De S.D., Kundel H.L., Arenson R.L., Et al., Eifect of a digital imaging network on physician behavior in an intensive care unit, Radiology, 169, pp. 41-44, (1988)
[2]  
Fraser R., Sanders C., Barnes G., Et al., Digital imaging of the chest, Radiology, 171, pp. 297-307, (1989)
[3]  
Goodman L.R., Wilson C.R., Foley W.D., Digital radiography of the chest: Promises and problems, AJR., 150, pp. 1241-1252, (1988)
[4]  
Merritt C.R., Matthews C.C., Scheinhorn D., Balter S., Digital imaging of the chest, J Thorac Imag., 1, 1, pp. 1-13, (1985)
[5]  
Merritt C.R.B., Photostimulable phosphors-clinical results, Proceedings of the Chest Imaging Conference 1987, pp. 208-211, (1988)
[6]  
Saito H., Kurashina T., Ishibashi T., Shimanuki Y., Sakamoto K., Digital radiography in an intensive care unit, Clin Radiol., 39, pp. 127-130, (1988)
[7]  
Blume H., Stimulable phosphor systems-technical aspects, Proceedings of the Chest Imaging Conference 1987, pp. 194-207, (1988)
[8]  
Sorenson J., Mitchell C., Evaluation of optical unsharp masking and contrast enhancement of low-scatter chest radiographs, AJR., 149, pp. 275-281, (1987)
[9]  
Fajardo L.L., Hillman B.J., Pond G.D., Carmody R.F., Johnson J.E., Ferrell W.R., Detection of pneumothorax: Comparison of digital and conventional chest imaging, AJR., 152, pp. 475-480, (1989)
[10]  
Fisher P.D., Brauer G.W., Impact of image size on effectiveness of digital imaging systems, J Diagn Imaging., 2, pp. 39-41, (1989)