Mercurated polystyrene (R-Hg-Ac) was employed as a sensor in a membrane electrode sensitive to anionic surfactants. A Nernstian dependence over the concentration range of sodium dodecyl sulphate of from 1 × 10-3 to 1 × 10-7 M and a high selectivity for anionic surfactants relative to inorganic anions were found for the electrode. Moreover, the electrode shows interesting properties towards hydroxyl ions. The electrode may find application in the analysis of surfactants, as an indicator electrode in the potentiometric titration of both cationic and anionic surfactants and in the physico-chemical studies of surfactant solutions.
引用
收藏
页码:1451 / 1455
页数:5
相关论文
共 43 条
[1]   GAS-LIQUID-CHROMATOGRAPHY OF STRAIGHT CHAIN HOMOLOGS OF ALKYLBENZYLDIMETHYLAMMONIUM COMPOUNDS [J].
ABIDI, SL .
JOURNAL OF CHROMATOGRAPHY, 1980, 200 (NOV) :216-220
[2]   CRITICAL MICELLE CONCENTRATION (CMC) DETERMINATION WITH AID OF LIQUID MEMBRANE ELECTRODE SENSITIVE TO DODECYL-SULFATE ANION [J].
ANGHEL, D ;
CIOCAN, N .
COLLOID AND POLYMER SCIENCE, 1976, 254 (01) :114-115
[3]   SURFACTANT-SELECTIVE ELECTRODES .2. USE OF PERM-SELECTIVE MEMBRANES [J].
BIRCH, BJ ;
CLARKE, DE .
ANALYTICA CHIMICA ACTA, 1974, 69 (02) :473-477
[4]   ELECTRODE SELECTIVE TO DODECYL SULFATE ANION - COMMENTS ON APPLICATION OF DIRECT POTENTIOMETRY TO CMC MEASUREMENTS [J].
BIRCH, BJ ;
CLARKE, DE .
ANALYTICA CHIMICA ACTA, 1972, 61 (01) :159-&
[5]   SURFACTANT-SELECTIVE ELECTRODES .1. IMPROVED LIQUID ION-EXCHANGER [J].
BIRCH, BJ ;
CLARKE, DE .
ANALYTICA CHIMICA ACTA, 1973, 67 (02) :387-393
[6]   LIQUID LIQUID EXTRACTION IN CONTINUOUS-FLOW SYSTEMS WITHOUT PHASE-SEPARATION [J].
CANETE, F ;
RIOS, A ;
DECASTRO, MDL ;
VALCARCEL, M .
ANALYTICAL CHEMISTRY, 1988, 60 (21) :2354-2357
[7]  
CHAMIOTAKIS NA, 1989, ANAL CHEM, V61, P566
[8]   TITRATION OF ANIONIC SURFACTANTS IN A MIXTURE, USING A SURFACTANT EXTRACTIVE ELECTRODE [J].
CIOCAN, N ;
ANGHEL, DF .
ANALYTICAL LETTERS, 1976, 9 (08) :705-711
[9]   ION-EXTRACTIVE LIQUID-MEMBRANE ANIONIC SURFACTANT SENSITIVE ELECTRODE AND ITS ANALYTICAL APPLICATIONS [J].
CIOCAN, N ;
ANGHEL, DF .
FRESENIUS ZEITSCHRIFT FUR ANALYTISCHE CHEMIE, 1978, 290 (03) :237-240
[10]  
CIOCAN N, 1976, TENSIDE DETERGENTS, V13, P188