ION-SELECTIVE ELECTRODE FOR INTRACELLULAR POTASSIUM MEASUREMENTS

被引:20
作者
HAEMMERLI, A
JANATA, J
BROWN, HM
机构
[1] UNIV UTAH,DEPT BIOENGN,SALT LAKE CITY,UT 84112
[2] UNIV UTAH,DEPT PHYSIOL,SALT LAKE CITY,UT 84112
关键词
D O I
10.1021/ac50058a006
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
引用
收藏
页码:1179 / 1182
页数:4
相关论文
共 11 条
[1]  
BROWN HC, UNPUBLISHED
[2]   INTRACELLULAR NA+, K+, AND CL- ACTIVITIES IN BALANUS-PHOTORECEPTORS [J].
BROWN, HM .
JOURNAL OF GENERAL PHYSIOLOGY, 1976, 68 (03) :281-296
[3]   FIELD-EFFECT TRANSISTOR AS A SOLID-STATE REFERENCE ELECTRODE [J].
COMTE, PA ;
JANATA, J .
ANALYTICA CHIMICA ACTA, 1978, 101 (02) :247-252
[4]  
FEIN H, 1977, INTRO MICROELECTRODE, P1
[5]  
JANATA J, 1979, ION SELECTIVE ELECTR, V1, P31
[6]  
MORF WE, 1978, ION SELECTIVE ELECTR, pCH3
[7]  
PUNGOR E, 1978, ION SELECTIVE ELECTR, pCH2
[8]  
THOMAS RC, 1978, ION SENSITIVE INTRAC, pCH8
[9]  
Walker J L, 1979, Methods Enzymol, V56, P359
[10]   ION SPECIFIC LIQUID ION EXCHANGER MICROELECTRODES [J].
WALKER, JL .
ANALYTICAL CHEMISTRY, 1971, 43 (03) :A89-&