CAPILLARY ELECTROPHORESIS ATMOSPHERIC-PRESSURE IONIZATION MASS-SPECTROMETRY FOR THE CHARACTERIZATION OF PEPTIDES - INSTRUMENTAL CONSIDERATIONS FOR MASS-SPECTROMETRIC DETECTION

被引:80
作者
JOHANSSON, IM
HUANG, EC
HENION, JD
ZWEIGENBAUM, J
机构
[1] CORNELL UNIV,925 WARREN DR,ITHACA,NY 14850
[2] EASTMAN KODAK CO,DIV ANALYT TECHNOL,ROCHESTER,NY 14652
来源
JOURNAL OF CHROMATOGRAPHY | 1991年 / 554卷 / 1-2期
关键词
D O I
10.1016/S0021-9673(01)88459-4
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
On-line capillary electrophoresis (CE) separations are shown for a synthetic peptide mixture and a tryptic digest of human hemoglobin in an uncoated fused-silica capillary with detection using atmospheric pressure ionization mass spectrometry (API-MS). The CE system utilized a 1-m capillary column of either 75- or 100-mu-m I.D. These somewhat larger inside diameters allow higher sample capacities for MS detection, and the 1-m length facilitates connecting the CE column to the liquid junction-ion spray interface and MS system. Low volatile buffer concentrations (15-20 mM) of ammonium acetate or ammonium formate, and high organic modifier content (5-50%) of methanol or acetonitrile facilitates ionization under electrospray conditions. This study shows that peptides separated by CE may be transferred to the API-MS system through a liquid junction coupling to the pneumatically assisted electrospray (ion spray) interface at low buffer pH when the electroosmotic flow is low (0-0.4-mu-l/min). CE-MS as described herein is facilitated by features in modern CE instrumentation including robotic cleaning and pressurization of the capillary inlet. The latter is particularly useful for repetitive rinsing and conditioning of the capillary column between analyses in addition to continuous 'infusion' of sample to the mass spectrometer for tuning purposes. In addition to facile molecular weight determination, amino acid sequence information for peptides may be obtained by utilizing on-line tandem MS. After the tryptic digest sample components enter the API-MS system, the molecular ion species of individual peptides may be focussed and transmitted into the collision cell of the tandem triple quadrupole mass spectrometer. Collision-induced dissociation of protonated peptide molecules yielded structural information for their characterization following injection of 10 pmol of a tryptic digest from human hemoglobin.
引用
收藏
页码:311 / 327
页数:17
相关论文
共 29 条
  • [1] ALTRIA KD, 1986, ANAL P, V23, P453
  • [2] [Anonymous], 1989, J MICROCOLUMN SEP, DOI DOI 10.1002/mcs.1220010105
  • [3] ION SPRAY INTERFACE FOR COMBINED LIQUID CHROMATOGRAPHY/ATMOSPHERIC PRESSURE IONIZATION MASS-SPECTROMETRY
    BRUINS, AP
    COVEY, TR
    HENION, JD
    [J]. ANALYTICAL CHEMISTRY, 1987, 59 (22) : 2642 - 2646
  • [4] COUPLING CAPILLARY ZONE ELECTROPHORESIS AND CONTINUOUS-FLOW FAST ATOM BOMBARDMENT MASS-SPECTROMETRY FOR THE ANALYSIS OF PEPTIDE MIXTURES
    CAPRIOLI, RM
    MOORE, WT
    MARTIN, M
    DAGUE, BB
    WILSON, K
    MORING, S
    [J]. JOURNAL OF CHROMATOGRAPHY, 1989, 480 : 247 - 257
  • [5] TANDEM MASS-SPECTROMETRY METHODOLOGY FOR THE SEQUENCE DETERMINATION OF CYCLIC-PEPTIDES
    ECKART, K
    SCHWARZ, H
    TOMER, KB
    GROSS, ML
    [J]. JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1985, 107 (24) : 6765 - 6769
  • [6] EFFECT OF ADDITION OF ORGANIC-SOLVENT ON THE SEPARATION OF POSITIONAL ISOMERS IN HIGH-VOLTAGE CAPILLARY ZONE ELECTROPHORESIS
    FUJIWARA, S
    HONDA, S
    [J]. ANALYTICAL CHEMISTRY, 1987, 59 (03) : 487 - 490
  • [7] APPLICATION OF FREE-SOLUTION CAPILLARY ELECTROPHORESIS TO THE ANALYTICAL SCALE SEPARATION OF PROTEINS AND PEPTIDES
    GROSSMAN, PD
    COLBURN, JC
    LAUER, HH
    NIELSEN, RG
    RIGGIN, RM
    SITTAMPALAM, GS
    RICKARD, EC
    [J]. ANALYTICAL CHEMISTRY, 1989, 61 (11) : 1186 - 1194
  • [8] EFFECT OF BUFFER PH AND PEPTIDE COMPOSITION ON THE SELECTIVITY OF PEPTIDE SEPARATIONS BY CAPILLARY ZONE ELECTROPHORESIS
    GROSSMAN, PD
    WILSON, KJ
    PETRIE, G
    LAUER, HH
    [J]. ANALYTICAL BIOCHEMISTRY, 1988, 173 (02) : 265 - 270
  • [9] GROSSMAN PD, 1990, AM BIOTECHNOL LA FEB, P35
  • [10] ATMOSPHERIC-PRESSURE IONIZATION MASS-SPECTROMETRY - DETECTION FOR THE SEPARATION SCIENCES
    HUANG, EC
    WACHS, T
    CONBOY, JJ
    HENION, JD
    [J]. ANALYTICAL CHEMISTRY, 1990, 62 (13) : A713 - +