RECOGNITION OF MULTIPLE TACHYARRHYTHMIAS BY RATE-INDEPENDENT MEANS USING A SMALL MICROCOMPUTER

被引:8
作者
TOOLEY, MA [1 ]
DAVIES, DW [1 ]
NATHAN, AW [1 ]
CAMM, AJ [1 ]
机构
[1] ST BARTHOLOMEWS HOSP,DEPT CARDIOL,LONDON EC1A 7BE,ENGLAND
来源
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY | 1991年 / 14卷 / 02期
关键词
TACHYCARDIA RECOGNITION; ANTITACHYCARDIA PACING;
D O I
10.1111/j.1540-8159.1991.tb05117.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
New implantable devices are now available that can offer different therapies for different arrhythmias but they need a method of discriminating between these rhythms. Heart rate analysis is predominantly used to discern between sinus rhythm (SR) and pathological tachycardias but this may be of limited value when the rates of the rhythms are similar. An enhanced form of Gradient Pattern Detection (GPD) has been developed using an 8-bit microcomputer that can distinguish between SR and up to three other arrhythmias in real time. This is a method based on electrogram morphology where each rhythm's specific electrogram is classified by a sequence of gradient 'zones'. The microprocessor of the computer is of similar processing power to ones used in current pacemakers. Five patients with multiple arrhythmias were studied. Four had ventricular tachycardia (VT) and one had three conduction patterns during supraventricular tachycardia (SVT). Bipolar endocardial right ventricular electrograms were recorded during SR and tachycardia in all patients. The computer would first 'learn' about each different rhythm by a semi-automatic means. Once all the rhythms were learned the program would enter the GPD analysis phase. The computer would output a series of real-time rhythm specific marker codes onto a chart recorder as it recognized each rhythm. Sixteen different arrhythmias (13 VT, 3 SVT) were examined for this study. All rhythms (including SR) were distinguished from each other except in the case of one patient with six VTs where two VTs had identical shapes and therefore could not be detected apart. The method would be a useful addition to heart rate analysis for future generations of microprocessor assisted pacemakers.
引用
收藏
页码:337 / 340
页数:4
相关论文
共 16 条
[1]   TACHYCARDIA RECOGNITION BY IMPLANTABLE ELECTRONIC DEVICES [J].
CAMM, AJ ;
DAVIES, DW ;
WARD, DE .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1987, 10 (05) :1175-1190
[2]  
Cochrane T., 1987, Measurement, V5, P34, DOI 10.1016/0263-2241(87)90026-1
[3]  
DAVIES DW, 1985, CIRCULATION, V72, P475
[4]   DETECTION OF PATHOLOGICAL TACHYCARDIA BY ANALYSIS OF ELECTROGRAM MORPHOLOGY [J].
DAVIES, DW ;
WAINWRIGHT, RJ ;
TOOLEY, MA ;
LLOYD, D ;
NATHAN, AW ;
SPURRELL, RAJ ;
CAMM, AJ .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1986, 9 (02) :200-208
[5]  
DAVIES DW, 1987, NONPHARMACOLOGICAL T, P421
[6]  
HAMILTON PS, 1987, IEEE ENG MED BIOL SO, V4, P1881
[7]   IDENTIFICATION OF VENTRICULAR-TACHYCARDIA WITH USE OF THE MORPHOLOGY OF THE ENDOCARDIAL ELECTROGRAM [J].
LANGBERG, JJ ;
GIBB, WJ ;
AUSLANDER, DM ;
GRIFFIN, JC .
CIRCULATION, 1988, 77 (06) :1363-1369
[8]   TERMINATION OF MALIGNANT VENTRICULAR ARRHYTHMIAS WITH AN IMPLANTED AUTOMATIC DEFIBRILLATOR IN HUMAN-BEINGS [J].
MIROWSKI, M ;
REID, PR ;
MOWER, MM ;
WATKINS, L ;
GOTT, VL ;
SCHAUBLE, JF ;
LANGER, A ;
HEILMAN, MS ;
KOLENIK, SA ;
FISCHELL, RE ;
WEISFELDT, ML .
NEW ENGLAND JOURNAL OF MEDICINE, 1980, 303 (06) :322-324
[9]   CLINICAL-EXPERIENCE WITH A SOFTWARE BASED TACHYCARDIA REVERSION PACEMAKER [J].
NATHAN, AW ;
CREAMER, JE ;
DAVIES, DW ;
CAMM, AJ .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1986, 9 (06) :1312-1315
[10]   FREQUENCY-SPECTRA OF VENTRICULAR-TACHYCARDIA AND SINUS RHYTHM IN HUMAN INTRACARDIAC ELECTROGRAMS - APPLICATION TO TACHYCARDIA DETECTION FOR CARDIAC-PACEMAKERS [J].
PANNIZZO, F ;
FURMAN, S .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1988, 35 (06) :421-425