FLOW CAPACITY OF INTERNAL MAMMARY ARTERY GRAFTS - EARLY RESTRICTION AND LATER IMPROVEMENT ASSESSED BY DOPPLER GUIDE-WIRE - COMPARISON WITH SAPHENOUS-VEIN GRAFTS

被引:80
作者
AKASAKA, T [1 ]
YOSHIKAWA, J [1 ]
YOSHIDA, K [1 ]
MAEDA, K [1 ]
HOZUMI, T [1 ]
NASU, M [1 ]
SHOMURA, T [1 ]
机构
[1] KOBE GEN HOSP,DEPT CARDIAC SURG,CHUO KU,KOBE 650,JAPAN
关键词
D O I
10.1016/0735-1097(94)00448-Y
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives. The purpose of this study was to assess flow dynamics and Row capacities of internal mammary artery and saphenous vein grafts to the left anterior descending coronary artery. Background. The postoperative bow capacity of internal mammary artery grafts to the left anterior descending coronary artery has been reported to be restricted compared with that of saphenous vein grafts in studies using radionuclide angiography. A recently developed Doppler guide wire has been used to analyze the Row dynamics of bypass grafts and to clarify the mechanism of this limited Row capacity. Methods. Phasic Row velocity recordings were obtained in the midportion of the bypass graft and within the native left anterior descending artery, using a 0.018-in. (0.046-cm) 12-MHz Doppler guide wire, in 53 patients: 27 patients with an internal mammary artery graft (16 with a new graft assessed 1 month postoperatively and Il with an old graft assessed at 1 year) and 26 patients with a saphenous vein graft (13 with a new graft assessed 1 month postoperatively and 13 with an old graft assessed at 1 year). All patients were studied at baseline rest and during hyperemia induced by intravenous infusion of dipyridamole, 0.56 mg/kg body weight, over 4 min. Results. In the left anterior descending artery itself, systolic and diastolic peak velocities, the time average of the instantaneous spectral peak velocity (time averaged peak velocity), vessel diameter and the calculated flow volume did not differ significantly among the four graft groups. The time averaged peak velocity was significantly greater for new than for old arterial grafts or for new or old vein grafts (mean +/- SD 27 +/- 9 vs. 19 +/- 6, 11 +/- 5 and 12 +/- 6 cm/s, respectively, p < 0.01). However, because the diameter of new arterial grafts was significantly smaller than that of the other three grafts (2.4 +/- 0.1 vs. 2.9 +/- 0.2 [p < 0.05], 3.6 +/- 0.6 [p < 0.01] and 3.4 +/- 0.5 mm [p < 0.01], respectively), there was no difference in calculated flow volumes at rest (62 +/- 17 vs. 58 +/- 15, 61 +/- 18 and 58 +/- 19 ml/min, respectively, p = NS) between new arterial grafts and the other grafts. Although the maximal time-averaged peak velocity during hyperemia was significantly greater in new than in old arterial grafts or new or old vein grafts (47 +/- 17 vs. 40 +/- 7, 31 +/- 8 and 34 +/- 12 cm/s, respectively, p < 0.01), the flow reserve of new arterial grafts was significantly smaller than that of the other three groups (1.8 +/- 0.3 vs. 2.6 +/- 0.3, 2.8 +/- 0.5 and 3.0 +/- 0.6, respectively, p < 0.01) because the baseline time-averaged peak velocity of these new grafts was far greater than that of the other groups. Conclusions. Internal mammary artery graft how early after operation is characterized by a higher rest velocity than that of vein graft flow. This high velocity maintains Row volume at baseline condition in compensation for the smaller diameter. Although Row reserve does not differ significantly between new and old vein grafts, that for internal mammary artery grafts is significantly reduced soon after bypass surgery. This restricted flow capacity improves late postoperatively because of an increase in diameter and a decrease in Row velocity from baseline levels.
引用
收藏
页码:640 / 647
页数:8
相关论文
共 23 条
  • [1] BACH RG, 1993, CIRCULATION, V88, P133
  • [2] BARNER HB, 1985, J THORAC CARDIOV SUR, V90, P668
  • [3] BARNER HB, 1973, AM HEART J, V86, P570
  • [4] CAMERON A, 1986, CIRCULATION, V74, P30
  • [5] TRANSCUTANEOUS ULTRASOUND MEASUREMENT OF BLOOD-FLOW IN INTERNAL MAMMARY ARTERY TO CORONARY-ARTERY GRAFTS
    DEBONO, DP
    SAMANI, NJ
    SPYT, TJ
    HARTSHORNE, T
    THRUSH, AJ
    EVANS, DH
    [J]. LANCET, 1992, 339 (8790) : 379 - 381
  • [6] VALIDATION OF A DOPPLER GUIDE WIRE FOR INTRAVASCULAR MEASUREMENT OF CORONARY-ARTERY FLOW VELOCITY
    DOUCETTE, JW
    CORL, PD
    PAYNE, HM
    FLYNN, AE
    GOTO, M
    NASSI, M
    SEGAL, J
    [J]. CIRCULATION, 1992, 85 (05) : 1899 - 1911
  • [7] COMPARATIVE HEMODYNAMIC PROPERTIES OF VEIN AND MAMMARY ARTERY IN CORONARY-BYPASS OPERATIONS
    FLEMMA, RJ
    SINGH, HM
    TECTOR, AJ
    LEPLEY, D
    FRAZIER, BL
    [J]. ANNALS OF THORACIC SURGERY, 1975, 20 (06) : 619 - 627
  • [8] COMPARISON OF BLOOD-FLOW VELOCITY WAVEFORMS IN DIFFERENT CORONARY-ARTERY BYPASS GRAFTS - SEQUENTIAL SAPHENOUS-VEIN GRAFTS AND INTERNAL MAMMARY ARTERY GRAFTS
    FUJIWARA, T
    KAJIYA, F
    KANAZAWA, S
    MATSUOKA, S
    WADA, Y
    HIRAMATSU, O
    KAGIYAMA, M
    OGASAWARA, Y
    TSUJIOKA, K
    KATSUMURA, T
    [J]. CIRCULATION, 1988, 78 (05) : 1210 - 1217
  • [9] COMPARISON OF CORONARY HEMODYNAMICS IN PATIENTS WITH INTERNAL MAMMARY ARTERY AND SAPHENOUS-VEIN CORONARY-ARTERY BYPASS GRAFTS - A NONINVASIVE APPROACH USING COMBINED 2-DIMENSIONAL AND DOPPLER ECHOCARDIOGRAPHY
    FUSEJIMA, K
    TAKAHARA, Y
    SUDO, Y
    MURAYAMA, H
    MASUDA, Y
    INAGAKI, Y
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1990, 15 (01) : 131 - 139
  • [10] CONTROL OF MYOCARDIAL OXYGEN CONSUMPTION - RELATIVE INFLUENCE OF CONTRACTILE STATE AND TENSION DEVELOPMENT
    GRAHAM, TP
    COVELL, JW
    SONNENBL.EH
    ROSS, J
    BRAUNWAL.E
    [J]. JOURNAL OF CLINICAL INVESTIGATION, 1968, 47 (02) : 375 - &