DETERMINATION OF CD4 AND CD8 LYMPHOCYTE SUBSETS BY A NEW ALTERNATIVE FLUORESCENCE IMMUNOASSAY

被引:7
作者
DENNY, TN
JENSEN, BD
GAVIN, EI
LOUZAO, AG
VELLA, FA
OLESKE, JM
WONG, W
机构
[1] UNIV MED & DENT NEW JERSEY,DEPT PEDIAT & PATHOL,NEWARK,NJ
[2] CHILDRENS HOSP,NEWARK,NJ
[3] ZYNAXIS INC,IN VITRO DIAGNOST,MALVERN,PA
关键词
D O I
10.1128/CDLI.2.3.330-336.1995
中图分类号
R392 [医学免疫学]; Q939.91 [免疫学];
学科分类号
100102 ;
摘要
The purpose of this study was to evaluate a new alternative fluorescence immunoassay method (Zymmune CD4/CD8 Cell Monitoring Kit; Zynaxis, Inc., Malvern, Pa.) for determining the absolute CD4(+) and CD8(+) T-lymphocyte concentrations in, whole blood. The investigation was performed as a two-site comparison of the reference whole blood flow cytometric method with the Zymmune method. In this investigation, a total of 166 patient samples were evaluated of which similar to 20% were from human immunodeficiency virus-positive individuals. The mean value for samples performed by the Zymmune CD4 assay was 1,094 (range, 74 to 2,586) cells per mu l, while the reference method yielded a mean of 890 (range, 35 to 2,033) cells per mu l. The correlation coefficient for regression analysis was 0.940. The mean value for samples performed by the Zymmune CD8 assay was 700 (range, 212 to 1,813) cells per mu l, while the reference method yielded a mean of 545 (range, 82 to 2,158) cells per yl. The correlation coefficient for regression analysis was 0.921. No site-specific differences or trends in CD4 or CD8 values were seen when the data were analyzed by site of collection. The average precision of the CD4 assay varied from 6 to 14%, corresponding to the high and low concentration ranges. For CD8, the average precision varied from 8.3 to 16% over the respective high to low concentration ranges, We conclude that the Zymmune CD4/CD8 Cell Monitoring Kit method provides absolute CD4(+) and CD8(+) T-lymphocyte concentrations which are equivalent to those given by the reference flow cytometric method.
引用
收藏
页码:330 / 336
页数:7
相关论文
共 26 条
[1]   GUIDELINE FOR FLOW CYTOMETRIC IMMUNOPHENOTYPING - A REPORT FROM THE NATIONAL-INSTITUTE-OF-ALLERGY-AND-INFECTIOUS-DISEASES, DIVISION OF AIDS [J].
CALVELLI, T ;
DENNY, TN ;
PAXTON, H ;
GELMAN, R ;
KAGAN, J .
CYTOMETRY, 1993, 14 (07) :702-715
[2]  
Clinical Applications of Flow Cytometry, 1992, H42T NAT COMM CLIN L
[3]   CLINICAL AND LABORATORY CORRELATES OF PNEUMOCYSTIS-CARINII PNEUMONIA IN CHILDREN INFECTED WITH HIV [J].
CONNOR, E ;
BAGARAZZI, M ;
MCSHERRY, G ;
HOLLAND, B ;
BOLAND, M ;
DENNY, T ;
OLESKE, J .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1991, 265 (13) :1693-1697
[4]   DECLINE IN CD4+ CELL NUMBERS REFLECTS INCREASE IN HIV-1 REPLICATION [J].
DEWOLF, F ;
ROOS, M ;
LANGE, JMA ;
HOUWELING, JTM ;
COUTINHO, RA ;
VANDERNOORDAA, J ;
SCHELLEKENS, PT ;
GOUDSMIT, J .
AIDS RESEARCH AND HUMAN RETROVIRUSES, 1988, 4 (06) :433-440
[5]  
FAHEY JL, 1990, NEW ENGL J MED, V222, P166
[6]   THE SAFETY AND EFFICACY OF ZIDOVUDINE (AZT) IN THE TREATMENT OF SUBJECTS WITH MILDLY SYMPTOMATIC HUMAN-IMMUNODEFICIENCY-VIRUS TYPE-1 (HIV) INFECTION - A DOUBLE-BLIND, PLACEBO-CONTROLLED TRIAL [J].
FISCHL, MA ;
RICHMAN, DD ;
HANSEN, N ;
COLLIER, AC ;
CAREY, JT ;
PARA, MF ;
HARDY, WD ;
DOLIN, R ;
POWDERLY, WG ;
ALLAN, JD ;
WONG, B ;
MERIGAN, TC ;
MCAULIFFE, VJ ;
HYSLOP, NE ;
RHAME, FS ;
BALFOUR, HH ;
SPECTOR, SA ;
VOLBERDING, P ;
PETTINELLI, C ;
ANDERSON, J .
ANNALS OF INTERNAL MEDICINE, 1990, 112 (10) :727-737
[7]   ASSESSMENT OF THE EFFECTS OF INSTRUMENTATION, MONOCLONAL-ANTIBODY, AND FLUOROCHROME ON FLOW CYTOMETRIC IMMUNOPHENOTYPING - A REPORT BASED ON 2 YEARS OF THE NIAID DAIDS FLOW-CYTOMETRY QUALITY ASSESSMENT PROGRAM [J].
GELMAN, R ;
CHENG, SC ;
KIDD, P ;
WAXDAL, M ;
KAGAN, J .
CLINICAL IMMUNOLOGY AND IMMUNOPATHOLOGY, 1993, 66 (02) :150-162
[8]   SELECTIVE ALTERATIONS IN IMMUNOREGULATORY LYMPHOCYTE SUBSETS IN EARLY HIV (HUMAN T-LYMPHOTROPIC VIRUS TYPE-III LYMPHADENOPATHY-ASSOCIATED VIRUS) INFECTION [J].
GIORGI, JV ;
NISHANIAN, PG ;
SCHMID, I ;
HULTIN, LE ;
CHENG, HL ;
DETELS, R .
JOURNAL OF CLINICAL IMMUNOLOGY, 1987, 7 (02) :140-150
[9]  
GIORGI JV, 1986, MANUAL CLIN LABORATO, P236
[10]  
Jackson A. L., 1986, MANUAL CLIN LABORATO, P226