DOPPLER ULTRASOUND SCANNING IN THE DETECTION OF RENAL-ARTERY STENOSIS IN HYPERTENSIVE PATIENTS

被引:64
作者
POSTMA, CT [1 ]
VANAALEN, J [1 ]
DEBOO, T [1 ]
ROSENBUSCH, G [1 ]
THIEN, T [1 ]
机构
[1] UNIV HOSP NIJMEGEN,DEPT MED STAT & DIAGNOST RADIOL,6500 HB NIJMEGEN,NETHERLANDS
关键词
DOPPLER ULTRASOUND SCANNING; RENAL ARTERY STENOSIS; HYPERTENSION;
D O I
10.1259/0007-1285-65-778-857
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The diagnostic accuracy of Doppler ultrasound in the detection of renal arterial disease has been assessed in a prospective study of 61 hypertensive patients. The findings of Doppler ultrasound were compared with the results of renal angiography. In 15 patients (24.5%) no accurate Doppler signs could be obtained and the Doppler ultrasound examination was considered a technical failure. Of the remaining 46 patients, 24 had renal artery stenosis. Nine of the stenoses were not detected by Doppler ultrasound and in three patients a false positive diagnosis of renal artery stenosis was made. The sensitivity of Doppler ultrasound was 62.5%, the specificity 86.4% and the overall diagnostic acccuracy was 73.9%. By comparing the 15 patients in whom Doppler ultrasound failed with the 46 in whom it was successful, age appeared to be higher and creatinine clearance lower in the failure group. By comparing the 34 patients with true positive and true negative results with the 12 patients with false results, no significant differences were found. In a multivariate analysis, higher age showed a significant relation to failure of Doppler ultrasound. Doppler ultrasound has limited value in the screening of hypertensive patients for renal artery stenosis.
引用
收藏
页码:857 / 860
页数:4
相关论文
共 17 条
[1]   PREDICTION OF RENOVASCULAR HYPERTENSION - COMPARISON OF CLINICAL DIAGNOSTIC INDEXES [J].
ANDERSON, GH ;
BLAKEMAN, N ;
STREETEN, DHP .
AMERICAN JOURNAL OF HYPERTENSION, 1988, 1 (03) :301-304
[2]   NONINVASIVE DIAGNOSIS OF RENAL-ARTERY STENOSIS BY ECHO-DOPPLER VELOCIMETRY [J].
AVASTHI, PS ;
VOYLES, WF ;
GREENE, ER .
KIDNEY INTERNATIONAL, 1984, 25 (05) :824-829
[3]   RENAL-ARTERY STENOSIS - PROSPECTIVE EVALUATION OF DIAGNOSIS WITH COLOR DUPLEX US COMPARED WITH ANGIOGRAPHY - WORK IN PROGRESS [J].
BERLAND, LL ;
KOSLIN, DB ;
ROUTH, WD ;
KELLER, FS .
RADIOLOGY, 1990, 174 (02) :421-423
[4]   PREDICTION OF CREATININE CLEARANCE FROM SERUM CREATININE [J].
COCKCROFT, DW ;
GAULT, MH .
NEPHRON, 1976, 16 (01) :31-41
[5]   RENAL-ARTERY STENOSIS - EVALUATION WITH COLOR DOPPLER FLOW IMAGING [J].
DESBERG, AL ;
PAUSHTER, DM ;
LAMMERT, GK ;
HALE, JC ;
TROY, RB ;
NOVICK, AC ;
NALLY, JV ;
WELTEVREDEN, AM .
RADIOLOGY, 1990, 177 (03) :749-753
[6]   RENAL-ARTERY STENOSIS - DUPLEX DOPPLER EVALUATION [J].
DUBBINS, PA .
BRITISH JOURNAL OF RADIOLOGY, 1986, 59 (699) :225-229
[7]   NON-INVASIVE CHARACTERIZATION OF RENAL-ARTERY BLOOD-FLOW [J].
GREENE, ER ;
VENTERS, MD ;
AVASTHI, PS ;
CONN, RL ;
JAHNKE, RW .
KIDNEY INTERNATIONAL, 1981, 20 (04) :523-529
[8]   A NEW ACCURATE AND NON-INVASIVE SCREENING METHOD FOR RENOVASCULAR HYPERTENSION - THE RENAL-ARTERY DOPPLER TECHNIQUE [J].
HANDA, N ;
FUKANAGA, R ;
OGAWA, S ;
MATSUMOTO, M ;
KIMURA, K ;
KAMADA, T .
JOURNAL OF HYPERTENSION, 1988, 6 :S458-S460
[9]   CAPTOPRIL RENOGRAPHY IN THE DIAGNOSIS OF RENAL-ARTERY STENOSIS - ACCURACY AND LIMITATIONS [J].
MANN, SJ ;
PICKERING, TG ;
SOS, TA ;
UZZO, RG ;
SARKAR, S ;
FRIEND, K ;
RACKSON, ME ;
LARAGH, JH .
AMERICAN JOURNAL OF MEDICINE, 1991, 90 (01) :30-40
[10]   THE CAPTOPRIL TEST AND RENOVASCULAR HYPERTENSION - A CAUTIONARY TALE [J].
MCCARTHY, JE ;
WEDER, AB .
ARCHIVES OF INTERNAL MEDICINE, 1990, 150 (03) :493-495