REPRODUCIBLE PACKING TECHNIQUE FOR CHROMATOGRAPHIC SILICA-GEL COLUMNS (5-10MUM)

被引:15
作者
ELGASS, H [1 ]
ENGELHARDT, H [1 ]
HALASZ, I [1 ]
机构
[1] UNIV SAARLAND,D-6600 SAARBRUCKEN,FED REP GER
来源
FRESENIUS ZEITSCHRIFT FUR ANALYTISCHE CHEMIE | 1979年 / 294卷 / 2-3期
关键词
Chromatographie; HPLC; Verfahren zum Packen von Silicagel-Säulen;
D O I
10.1007/BF00523928
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A simple packing technique for silica gel is described that yields efficient HPLC columns with good reproducibility. The isopropanol/methanol (35/15, v/v) suspending medium used is relatively nontoxic, and the packing times can be kept short. Close adherence to the recommended procedure permits columns, 20-50 cm long, to be packed with comparable efficiency, even with silicas from different commercial sources. Their performance corresponds to that of well-packed columns as described in the literature between 1972 and 1978, which is reviewed chronologically. It is shown experimentally that the efficiency of columns of typical dimensions packed with 5 μm silica frequently cannot be fully exploited with current commercial instruments. © 1979 Springer-Verlag.
引用
收藏
页码:97 / 106
页数:10
相关论文
共 51 条
  • [1] REPRODUCIBILITY AND EFFICIENCY OF COLUMNS PACKED WITH 10 MU SILICA IN LIQUID-CHROMATOGRAPHY
    ASSHAUER, J
    HALASZ, I
    [J]. JOURNAL OF CHROMATOGRAPHIC SCIENCE, 1974, 12 (03) : 139 - 147
  • [2] BOHME W, 1977, J CHROMATOGRAPHY, V133, P67
  • [3] PACKING, PERFORMANCE AND PERMEABILITY OF LARGER AND WIDER LIQUID-CHROMATOGRAPHY COLUMNS AND THEIR USE IN PREPARING SAMPLES FOR IDENTIFICATION
    BRISTOW, PA
    [J]. JOURNAL OF CHROMATOGRAPHY, 1978, 149 (FEB): : 13 - 28
  • [4] UPWARD SLURRY PACKING OF LIQUID-CHROMATOGRAPHY COLUMNS
    BRISTOW, PA
    BRITTAIN, PN
    RILEY, CM
    WILLIAMSON, BF
    [J]. JOURNAL OF CHROMATOGRAPHY, 1977, 131 (JAN21): : 57 - 64
  • [5] STANDARDIZATION OF TEST CONDITIONS FOR HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY COLUMNS
    BRISTOW, PA
    KNOX, JH
    [J]. CHROMATOGRAPHIA, 1977, 10 (06) : 279 - 289
  • [6] STUDY OF PACKING TECHNIQUES FOR SMALL-PARTICLE SILICA-GELS IN HIGH-SPEED LIQUID-CHROMATOGRAPHY
    CASSIDY, RM
    LEGAY, DS
    FREI, RW
    [J]. ANALYTICAL CHEMISTRY, 1974, 46 (03) : 340 - 344
  • [7] HIGH-SPEED LIQUID-SOLID CHROMATOGRAPHY OF PHENOTHIAZINES USING COLUMNS PACKED WITH SPHEROSIL POROUS SILICA BEADS
    CAUDE, M
    LEXUANPHAN
    TERLAIN, B
    THOMAS, JP
    [J]. JOURNAL OF CHROMATOGRAPHIC SCIENCE, 1975, 13 (08) : 390 - 396
  • [8] CHANG SH, 1976, J CHROMATOGR, V125, P103, DOI 10.1016/S0021-9673(00)93814-7
  • [9] TECHNIQUES FOR PACKING HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC COLUMNS WITH POROUS MICROPARTICLES
    COQ, B
    GONNET, C
    ROCCA, JL
    [J]. JOURNAL OF CHROMATOGRAPHY, 1975, 106 (02): : 249 - 262
  • [10] CONTROL OF FLOW RATE IN HIGH PRESSURE LIQUID CHROMATOGRAPHY
    DEININGER, G
    HALASZ, I
    [J]. JOURNAL OF CHROMATOGRAPHY, 1971, 60 (01): : 65 - +