SINGLE-LEAD VDD PACING SYSTEM

被引:41
作者
VARRIALE, P
PILLA, AG
TEKRIWAL, M
机构
[1] Division of Cardiology, Cabrini Medical Center, New York, New York
来源
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY | 1990年 / 13卷 / 06期
关键词
atrial tracking; differential bipolar sensing; sensitivity threshold; single pass lead;
D O I
10.1111/j.1540-8159.1990.tb02102.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
A single pass ventricular lead with a dual chamber electrode system, designed for VDD pacing, was implanted in 17 patients (11 men, 6 women, aged 53 to 86 years, mean 74) for symptomatic bradycardia due to second‐or third‐degree AV block and normal sinus node function. Bipolar atrial electrodes, diagonally displaced along the lead axis and positioned within the right atrial cavity, are used to detect atrial activity that is then differentially processed within the pacemaker, P wave amplitude (amp) derived from a PSA‐DAA device at implant was 1.38 ± 0.28 mV. P wave signal amp derived from telemetered atrial electrograms was 1,29 ± 0.22 mV at predischarge (n = 17), 1.32 ± 0.24 mV at 3 months (n = 15), 1.30 ± 0.24 mVat 6 months (n =8), 1.51 ± 0.34 mVat 9 months (n = 4), and 1.35 ± 0.35 mV at 12 months (n = 2); and the far‐field QRS signal measured at predischarge was of negligible voltage (0.17 ± 0.07 mV). The susceptibility of the atrial sensor system to interference was noted with chest wall stimulation and only at higher sensitivities (0.1 to 0.3 mV) and not with isometric arm exercise. Intact VDD pacing function at rest and during exercise was established using Holter and periodic ECG monitoring. Postoperative complications included one lead displacement and one pocket hematoma. Three patients died postimplant of causes unrelated to pacemaker function. Advantages of the single‐lead VDD pacing include: (1) elimination of second atrial sensing lead; (2) superior atrial sensing performance; (3) effective resistance to myopotential and far‐field signal interference; and (4) stability of postimplant atrial signal amplitude. Copyright © 1990, Wiley Blackwell. All rights reserved
引用
收藏
页码:757 / 766
页数:10
相关论文
共 24 条
[1]   SENSING AND PACING WITH FLOATING ELECTRODES IN THE RIGHT ATRIUM AND RIGHT ATRIAL APPENDAGE [J].
AUBERT, AE ;
GOLDREYER, BN ;
WYMAN, MG ;
ECTOR, H ;
DENYS, BG ;
DEGEEST, H .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1987, 9 (02) :308-315
[2]   SIMULTANEOUS RIGHT ATRIAL APPENDAGE SENSING WITH A TARGET TIP, A SOLID TIP AND J-ORTHOGONAL ELECTRODES [J].
AUBERT, AE ;
GOLDREYER, BN ;
WYMAN, MG ;
DENYS, BG ;
ECTOR, H ;
DEGEEST, H .
AMERICAN JOURNAL OF CARDIOLOGY, 1987, 59 (06) :610-614
[3]   SENSING CHARACTERISTICS OF UNIPOLAR AND BIPOLAR ORTHOGONAL FLOATING ATRIAL ELECTRODES - MORPHOLOGY AND SPECTRAL-ANALYSIS [J].
AUBERT, AE ;
ECTOR, H ;
DENYS, BG ;
DEGEEST, H .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1986, 9 (03) :343-359
[4]   FAR-FIELD QRS COMPLEX SENSING VIA THE ATRIAL PACEMAKER LEAD .2. PREVALENCE, CLINICAL-SIGNIFICANCE AND POSSIBILITY OF INTRAOPERATIVE PREDICTION IN DDD PACING [J].
BRANDT, J ;
FAHRAEUS, T ;
SCHULLER, H .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1988, 11 (11) :1540-1544
[5]   FAR-FIELD QRS COMPLEX SENSING VIA THE ATRIAL PACEMAKER LEAD .1. MECHANISM, CONSEQUENCES, DIFFERENTIAL-DIAGNOSIS AND COUNTERMEASURES IN AAI AND VDD/DDD PACING [J].
BRANDT, J ;
FAHRAEUS, T ;
SCHULLER, H .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1988, 11 (10) :1432-1438
[6]   DECREASE IN CANINE ENDOCARDIAL AND EPICARDIAL ELECTROGRAM VOLTAGES WITH EXERCISE - IMPLICATIONS FOR PACEMAKER SENSING [J].
BRICKER, JT ;
WARD, KA ;
ZINNER, A ;
GILLETTE, PC .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1988, 11 (04) :460-464
[7]   TOWARD OPTIMIZING THE DETECTION OF ATRIAL DEPOLARIZATION WITH FLOATING BIPOLAR ELECTRODES [J].
BROWNLEE, RR .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1989, 12 (03) :431-442
[8]  
DEBOER H, 1988, PACE, V11, P158
[9]   ATRIAL SENSING PERFORMANCE OF AV UNIVERSAL PACEMAKERS DURING EXERCISE [J].
FROHLIG, G ;
BLANK, W ;
SCHWERDT, H ;
SEN, S ;
BETTE, L .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1988, 11 (01) :47-60
[10]   ATRIAL SIGNAL VARIATIONS AND PACEMAKER MALSENSING DURING EXERCISE - A STUDY IN THE TIME AND FREQUENCY-DOMAIN [J].
FROHLIG, G ;
SCHWERDT, H ;
SCHIEFFER, H ;
BETTE, L .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1988, 11 (04) :806-813