ECHOCARDIOGRAPHIC DETECTION OF CORONARY-ARTERY DISEASE DURING DOBUTAMINE INFUSION

被引:605
作者
SAWADA, SG
SEGAR, DS
RYAN, T
BROWN, SE
DOHAN, AM
WILLIAMS, R
FINEBERG, NS
ARMSTRONG, WF
FEIGENBAUM, H
机构
[1] INDIANA UNIV,SCH MED,DEPT MED,INDIANAPOLIS,IN 46202
[2] RICHARD L ROUDEBUSH VET ADM MED CTR,INDIANAPOLIS,IN 46202
[3] WISHARD MEM HOSP,INDIANAPOLIS,IN 46202
[4] KRANNERT CARDIOVASC RES INST,INDIANAPOLIS,IN
关键词
ECHOCARDIOGRAPHY; BETA-ADRENERGIC RECEPTOR AGONISTS; DOBUTAMINE; CORONARY ARTERY DISEASE;
D O I
10.1161/01.CIR.83.5.1605
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background. Two-dimensional echocardiography performed during dobutamine infusion has been proposed as a potentially useful method for detecting coronary artery disease. However, the safety and diagnostic value of dobutamine stress echocardiography has not been established. Methods and Results. In this study, echocardiograms were recorded during step-wise infusion of dobutamine to a maximum dose of 30-mu-g/kg/min in 103 patients who also underwent quantitative coronary angiography. The echocardiograms were digitally stored and displayed in a format that allowed simultaneous analysis of rest and stress images. Development of a new abnormality in regional function was used as an early end point for the dobutamine infusion. No patient had a symptomatic arrhythmia or complications from stress-induced ischemia. Significant coronary artery disease (greater-than-or-equal-to 50% diameter stenosis) was present in 35 of 55 patients who had normal echocardiograms at rest. The sensitivity and specificity of dobutamine-induced wall motion abnormalities for coronary artery disease was 89% (31 of 35) and 85% (17 of 20), respectively. The sensitivity was 81% (17 of 21) in those with one-vessel disease and 100% (14 of 14) in those with multivessel or left main disease. Forty-one of 48 patients with abnormal echocardiograms at baseline had localized rest wall motion abnormalities. Fifteen had coronary artery disease confined to regions that had abnormal rest wall motion, and 26 had disease remote from these regions. Thirteen of 15 patients (87%) without remote disease did not develop remote stress-induced abnormalities, and 21 of 26 (81%) who had remote disease developed corresponding abnormalities. Conclusions. Echocardiography combined with dobutamine infusion is a safe and accurate method for detecting coronary artery disease and for predicting the extent of disease in those who have localized rest wall motion abnormalities.
引用
收藏
页码:1605 / 1614
页数:10
相关论文
共 30 条
  • [1] APPLEGATE RJ, 1986, ECHOCARDIOGR-J CARD, V3, P333
  • [2] COMPLEMENTARY VALUE OF TWO-DIMENSIONAL EXERCISE ECHOCARDIOGRAPHY TO ROUTINE TREADMILL EXERCISE TESTING
    ARMSTRONG, WF
    ODONNELL, J
    DILLON, JC
    MCHENRY, PL
    MORRIS, SN
    FEIGENBAUM, H
    [J]. ANNALS OF INTERNAL MEDICINE, 1986, 105 (06) : 829 - 835
  • [3] EFFECT OF PRIOR MYOCARDIAL-INFARCTION AND EXTENT AND LOCATION OF CORONARY-DISEASE ON ACCURACY OF EXERCISE ECHOCARDIOGRAPHY
    ARMSTRONG, WF
    ODONNELL, J
    RYAN, T
    FEIGENBAUM, H
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1987, 10 (03) : 531 - 538
  • [4] BERNSTEIN RF, 1984, CIRCULATION S2, V7, P184
  • [5] PREDICTING THE EXTENT AND LOCATION OF CORONARY-ARTERY DISEASE IN ACUTE MYOCARDIAL-INFARCTION BY ECHOCARDIOGRAPHY DURING DOBUTAMINE INFUSION
    BERTHE, C
    PIERARD, LA
    HIERNAUX, M
    TROTTEUR, G
    LEMPEREUR, P
    CARLIER, J
    KULBERTUS, HE
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1986, 58 (13) : 1167 - 1172
  • [6] THE EFFECT OF DIFFERENT MECHANISMS OF MYOCARDIAL ISCHEMIA ON LEFT-VENTRICULAR FUNCTION
    CARLSON, RE
    KAVANAUGH, KM
    BUDA, AJ
    [J]. AMERICAN HEART JOURNAL, 1988, 116 (02) : 536 - 545
  • [7] CHATTERJEE K, 1989, DOBUTAMINE 10 YEAR R, P49
  • [8] USE OF THE EPINEPHRINE TEST IN DIAGNOSIS OF CORONARY-ARTERY DISEASE
    FERRARA, N
    LEOSCO, D
    LONGOBARDI, G
    ABETE, P
    PAPA, M
    VIGORITO, C
    RENGO, F
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1986, 58 (03) : 256 - 260
  • [9] A COMPARISON OF DOBUTAMINE INFUSION AND SUPINE BICYCLE EXERCISE FOR RADIONUCLIDE CARDIAC STRESS-TESTING
    FREEMAN, ML
    PALAC, R
    MASON, J
    BARNES, WE
    EASTMAN, G
    VIRUPANNAVAR, S
    LOEB, HS
    KAPLAN, E
    [J]. CLINICAL NUCLEAR MEDICINE, 1984, 9 (05) : 251 - 255
  • [10] FUJITA T, 1986, JPN HEART J, V27, P287