A COMPUTERIZED TECHNIQUE FOR THE QUANTITATIVE ASSESSMENT OF RESORPTION CAVITIES IN TRABECULAR BONE

被引:37
作者
GARRAHAN, NJ [1 ]
CROUCHER, PI [1 ]
COMPSTON, JE [1 ]
机构
[1] UNIV COLL CARDIFF,DEPT PATHOL,CARDIFF CF4 4XN,S GLAM,WALES
关键词
Histomorphometry; Resorption cavity; Resorption depth; Trabecular bone;
D O I
10.1016/8756-3282(90)90076-B
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
A computerised technique is described for the quantitative assessment of resorption cavities in iliac trabecular bone. Using an Ibas II image analyser, the original bone surface, eroded by bone resorbing cells, is reconstructed using a curve fitting technique that maintains a smooth continuity with the trabecular bone on either side of the cavity. Resorption depths are measured using an interactive elastic circle; all identified cavities are measured regardless of whether or not resorption is complete, and the measurements made include mean and maximum cavity depth, cavity length, area, and adjacent trabecular widths. Results in 13 normal subjects are presented. The technique is reproducible, simple to operate, relatively rapid, and can be applied to less sophisticated image analysis systems. © 1990.
引用
收藏
页码:241 / 245
页数:5
相关论文
共 13 条
  • [1] Birkenhager-Frenkel DH., 1976, BONE HISTOMORPHOMETR, P63
  • [2] BOYDE A, 1989, BONE, V10, P150
  • [3] INTEROBSERVER AND INTRAOBSERVER VARIATION IN BONE HISTOMORPHOMETRY
    COMPSTON, JE
    VEDI, S
    STELLON, AJ
    [J]. CALCIFIED TISSUE INTERNATIONAL, 1986, 38 (02) : 67 - 70
  • [4] COUPRON P, 1980, BONE HISTOMORPHOMETR, P323
  • [5] THE RELATIONSHIP BETWEEN RESORPTION DEPTH AND MEAN INTERSTITIAL BONE THICKNESS - AGE-RELATED-CHANGES IN MAN
    CROUCHER, PI
    MELLISH, RWE
    VEDI, S
    GARRAHAN, NJ
    COMPSTON, JE
    [J]. CALCIFIED TISSUE INTERNATIONAL, 1989, 45 (01) : 15 - 19
  • [6] MEAN WALL THICKNESS AND FORMATION PERIODS OF TRABECULAR BONE PACKETS IN IDIOPATHIC OSTEOPOROSIS
    DARBY, AJ
    MEUNIER, PJ
    [J]. CALCIFIED TISSUE INTERNATIONAL, 1981, 33 (03) : 199 - 204
  • [7] RECONSTRUCTION OF THE RESORPTIVE SITE IN ILIAC TRABECULAR BONE - A KINETIC-MODEL FOR BONE-RESORPTION IN 20 NORMAL INDIVIDUALS
    ERIKSEN, EF
    MELSEN, F
    MOSEKILDE, L
    [J]. METABOLIC BONE DISEASE & RELATED RESEARCH, 1984, 5 (05): : 235 - 242
  • [8] Frost HM, 1963, BONE REMODELING DYNA
  • [9] MEAN WALL THICKNESS OF TRABECULAR BONE PACKETS IN HUMAN ILIAC CREST - CHANGES WITH AGE
    LIPS, P
    COURPRON, P
    MEUNIER, PJ
    [J]. CALCIFIED TISSUE RESEARCH, 1978, 26 (01): : 13 - 17
  • [10] PALLE S, 1989, J BONE MINER RES, V4, P501