VOLUME MEASUREMENT BY ULTRASONIC TRANSVERSE OR SAGITTAL CROSS-SECTIONAL SCANNING

被引:18
作者
BASSET, O
GIMENEZ, G
MESTAS, JL
CATHIGNOL, D
DEVONEC, M
机构
[1] INSERM,U281,F-69008 LYONS,FRANCE
[2] HOP ANTIQUAILLE,SERV UROL,F-69321 LYONS 1,FRANCE
关键词
ACOUSTICS; ULTRASONICS; TOMOGRAPHIC SCANS; VOLUME MEASUREMENT; PROSTATIC ULTRASOUND;
D O I
10.1016/0301-5629(91)90050-7
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
A technique is described that provides an accurate estimation of the volume of an organ from its ultrasonic cross-sectional images. The technique is applied to two types of ultrasonic investigation, one providing transverse and the other sagittal images. The organ outline has to be traced on each scan. The computer first calculates the area and then the volume from the vector areas and the centroids of a series of sections. The technique has been tested with phantoms of various shapes and volumes made with agar gel. These experiments show that the error in the volume estimation is less than 10% and the variability of measurements is less than 2%.