DEVELOPMENT OF A DISPOSABLE AMPEROMETRIC SENSOR FOR REDUCED NICOTINAMIDE ADENINE-DINUCLEOTIDE BASED ON A CHEMICALLY-MODIFIED SCREEN-PRINTED CARBON ELECTRODE

被引:47
作者
SPRULES, SD
HART, JP
WRING, SA
PITTSON, R
机构
[1] UNIV W ENGLAND,FAC APPL SCI,BRISTOL BS16 1QY,AVON,ENGLAND
[2] GLAXO GRP RES LTD,DIV DRUG METAB,WARE SG12 0DP,HERTS,ENGLAND
[3] GWENT ELECTR MAT LTD,PONTYPOOL NP4 0H2,GWENT,WALES
关键词
AMPEROMETRY; SCREEN-PRINTING; MELDOLAS BLUE; NICOTINAMIDE ADENINE DINUCLEOTIDE;
D O I
10.1039/an9941900253
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The evaluation of novel, disposable, screen-printed electrodes by means of cyclic voltammetry with potassium hexacyanoferrate(II), phenazine methosulfate, and Meldola's Blue is described. Meldola's Blue was incorporated into selected electrodes, and the electrocatalytic oxidation of reduced nicotinamide adenine dinucleotide (NADH) was investigated using cyclic voltammetry and hydrodynamic voltammetry. The modified electrodes were used for quantitative measurements of NADH by means of amperometry in stirred solutions at applied potentials of -0.05 V (versus a saturated calomel electrode). The limit of detection was found to be 2.5 X 10(-6) mol dm(-3); the response was linear up to 2.5 x 10(-4) mol dm(-3).
引用
收藏
页码:253 / 257
页数:5
相关论文
共 14 条
[1]  
BOYER PD, 1975, ENZYMES, V11
[2]  
BUTCHELOR MJ, 1989, ANAL CHIM ACTA, V221, P289
[3]   MECHANISM OF THE OXIDATION OF NADH BY QUINONES - ENERGETICS OF ONE-ELECTRON AND HYDRIDE ROUTES [J].
CARLSON, BW ;
MILLER, LL .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1985, 107 (02) :479-485
[4]   A LYSINE DEHYDROGENASE-BASED ELECTRODE FOR BIOSENSING OF L-LYSINE [J].
DEMPSEY, E ;
WANG, J ;
WOLLENBERGER, U ;
OZSOZ, M ;
SMYTH, MR .
BIOSENSORS & BIOELECTRONICS, 1992, 7 (05) :323-327
[5]  
GALUS Z, 1976, FUNDAMENTALS ELECTRO, P237
[6]   PHENAZINE ETHOSULFATE AS A PREFERRED ELECTRON-ACCEPTOR TO PHENAZINE METHOSULFATE IN DYE-LINKED ENZYME ASSAYS [J].
GHOSH, R ;
QUAYLE, JR .
ANALYTICAL BIOCHEMISTRY, 1979, 99 (01) :112-117
[7]   VOLTAMMETRIC AND AMPEROMETRIC BEHAVIOR OF URIC-ACID AT BARE AND SURFACE-MODIFIED SCREEN-PRINTED ELECTRODES - STUDIES TOWARDS A DISPOSABLE URIC-ACID SENSOR [J].
GILMARTIN, MAT ;
HART, JP .
ANALYST, 1992, 117 (08) :1299-1303
[8]   ELECTROCATALYTIC OXIDATION OF REDUCED NICOTINAMIDE COENZYMES BY GRAPHITE-ELECTRODES MODIFIED WITH AN ADSORBED PHENOXAZINIUM SALT, MELDOLA BLUE [J].
GORTON, L ;
TORSTENSSON, A ;
JAEGFELDT, H ;
JOHANSSON, G .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1984, 161 (01) :103-120
[9]  
HIN BFYY, 1987, ANAL CHEM, V59, P2111
[10]   A UNIQUE BIOSENSING SYSTEM FOR PYRUVATE AND LACTATE USING A MEDIATOR-COEXISTED LACTATE DEHYDROGENASE-NAD CONDUCTIVE MEMBRANE [J].
IKARIYAMA, Y ;
ISHIZUKA, T ;
SINOHARA, H ;
AIZAWA, M .
DENKI KAGAKU, 1990, 58 (12) :1097-1102