SENSITIVE GAS-CHROMATOGRAPHIC ASSAY USING A NITROGEN-PHOSPHORUS DETECTOR FOR DETERMINATION OF ANTIPYRINE AND AMINOPYRINE IN BIOLOGICAL-FLUIDS

被引:12
作者
SHIVELY, CA [1 ]
SIMONS, RJ [1 ]
VESELL, ES [1 ]
机构
[1] PENN STATE UNIV, MILTON S HERSHEY MED CTR, COLL MED, DEPT PHARMACOL, HERSHEY, PA 17033 USA
关键词
D O I
10.1159/000137317
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
A method using gas chromatography with organic nitrogen-sensitive detection is described for measurement of antipyrine and aminopyrine concentrations in biological fluids. The analysis was performed isothermally on 3% SP-2250 DB after alkalinized saliva was extracted into chloroform. Phenacetin served as internal standard. Low oral doses of antipyrine (1.0-1.8 mg/kg) and/or aminopyrine (2 mg/kg) were measured accurately in saliva of normal human subjects. The standard curves for antipyrine and aminopyrine were linear from 0 to 10 μg/ml. The coefficient of variation, determined at a salivary concentration of 2 μg/ml, was 1.7% for antipyrine and 2.4% for aminopyrine. Saliva concentrations obtained by this method in normal human subjects after either an oral dose of antipyrine (18 mg/kg) or aminopyrine (9 mg/kg) agreed closely with those determined by the flame ionization gas-chromatographic method used to measure higher concentrations of antipyrine and aminopyrine. Antipyrine (1.8 mg/kg) administered concomitantly with aminopyrine (1 mg/kg or 2 mg/kg) to normal male volunteers prolonged mean saliva antipyrine half-life by about 25-33% compared to values obtained when these same subjects received the same dose of antipyrine alone.
引用
收藏
页码:228 / 236
页数:9
相关论文
共 21 条
  • [1] ANDREASE.B, 1974, EUR J CLIN INVEST, V4, P129
  • [2] DETERMINANTS OF SERUM ANTIPYRINE HALF-LIVES IN PATIENTS WITH LIVER-DISEASE
    BRANCH, RA
    HERBERT, CM
    READ, AE
    [J]. GUT, 1973, 14 (07) : 569 - 573
  • [3] CLINICAL IMPLICATIONS OF ENZYME INDUCTION
    BRECKENRIDGE, A
    ORME, M
    [J]. ANNALS OF THE NEW YORK ACADEMY OF SCIENCES, 1971, 179 (JUL6) : 421 - +
  • [4] BRODIE BB, 1949, J BIOL CHEM, V179, P25
  • [5] BRODIE BB, 1950, J PHARMACOL EXP THER, V99, P171
  • [6] BRODIE BB, 1950, J PHARMACOL EXP THER, V98, P97
  • [7] CHANG RL, 1976, CLIN PHARMACOL THER, V20, P219
  • [8] ELIN RJ, 1975, CLIN PHARMACOL THER, V17, P447
  • [9] HEPNER GW, 1977, J LAB CLIN MED, V90, P440
  • [10] IONIZATION DETECTOR FOR GAS-CHROMATOGRAPHY WITH SWITCHABLE SELECTIVITY FOR CARBON, NITROGEN AND PHOSPHORUS
    KOLB, B
    AUER, M
    POSPISIL, P
    [J]. JOURNAL OF CHROMATOGRAPHY, 1977, 134 (01): : 65 - 71